Registro não-rígido de imagens médicas usando block-based principal component analysis como camada de pooling

dc.contributor.advisorSalvadeo, Denis Henrique Pinheiro [UNESP]
dc.contributor.authorPinheiro Junior, Uemerson
dc.date.accessioned2024-04-24T12:00:47Z
dc.date.available2024-04-24T12:00:47Z
dc.date.issued2024-03-04
dc.description.abstractO registro não-rígido de imagem é fundamental em muitas tarefas de análise em imagens médicas. O registro não-rígido visa estabelecer correspondências espaciais com o intuito de minimizar as diferenças entre a imagem fixa e a imagem móvel. As técnicas convencionais de registro de imagens, devido à abordagem iterativa, são lentas, mesmo se realizada com as melhores técnicas e com as melhores GPUs. Além disso, possui dificuldades com convergência ou estagnação prematura, principalmente com imagens multimodais. Desta forma, recentemente, foi introduzida na literatura a abordagem de registro de imagem com aprendizado profundo visando resolver os problemas de lentidão, de convergência ou estagnação prematura dos métodos convencionais. Algumas destas novas abordagens são baseadas na rede U-Net, utilizando camadas clássicas de pooling, tal como o Max Pooling, que não consideram a relação espacial para realizar uma compressão mais representativa dos dados. Por outro lado, outras técnicas perdem a relação espacial dos dados, como o uso da análise de componentes principais (PCA) global como pooling. Assim, o presente trabalho tem o objetivo de investigar a utilização da técnica PCA baseada em Blocos (Block-based PCA, i.e., BPCA) como técnica de pooling para ambas as etapas de subamostragem e reconstrução de uma U-Net aplicada ao problema de registro de imagens médicas. A fim de analisar a efetividade desse método, foram realizados experimentos nos conjuntos de dados OASIS e IXI, que são conjuntos de dados de imagens 3D de ressonância magnética ponderadas em T1 do cérebro. Os experimentos revelaram que o BPCA superou o Max Pooling no conjunto de dados IXI e apresentou desempenho equivalente no conjunto de dados de validação do OASIS, apresentando valores inferiores apenas no conjunto de testes do OASIS. Além disso, a combinação dos dois métodos, em que o BPCA é utilizado nas três camadas iniciais de pooling e, na última camada, o Max Pooling, superou os resultados dos outros experimentos na métrica Dice. Assim, com os resultados qualitativos e quantitativos, foi demonstrado que o método BPCA é uma alternativa viável para o registro não-rígido de imagens.pt
dc.description.abstractThe non-rigid image registration is fundamental in many tasks of analysis in medical images. Non-rigid registration aims to establish spatial correspondences with the purpose of minimizing differences between the fixed and moving images. Conventional image registration techniques, due to their iterative approach, are slow, even when implemented with the best techniques and GPUs. Moreover, they encounter difficulties with convergence or premature stagnation, particularly with multimodal images. Thus, a recent introduction in the literature is the deep learning-based image registration approach, aiming to address the issues of slowness, convergence, or premature stagnation encountered by conventional methods. Some of these new approaches are based on the U-Net architecture, utilizing classical pooling layers such as Max Pooling, which do not consider spatial relationships for a more representative data compression. On the other hand, other techniques lose the spatial relationship of the data, such as the use of global Principal Component Analysis (PCA) as pooling. Therefore, the present study aims to investigate the use of Block-based PCA (BPCA) as a pooling technique for both downsampling and upsampling stages of a U-Net applied to the medical image registration problem. In order to analyze the effectiveness of this method, experiments were conducted on the OASIS and IXI datasets, which are datasets of 3D T1-weighted brain magnetic resonance images. The experiments revealed that BPCA outperformed Max Pooling in the IXI dataset and showed equivalent performance in the OASIS validation dataset, presenting lower values only in the OASIS test dataset. Furthermore, the combination of both methods, where BPCA is used in the initial three pooling layers and Max Pooling is applied in the final layer, surpassed the results of other experiments in the Dice metric. Thus, with qualitative and quantitative results, it was demonstrated that the BPCA method is a viable alternative for non-rigid image registration.en
dc.description.sponsorshipNão recebi financiamentopt
dc.identifier.urihttps://hdl.handle.net/11449/255307
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.subjectRegistro não-rígido de imagempt
dc.subjectImagens médicaspt
dc.subjectAprendizado profundopt
dc.subjectAnálise de componentes principaispt
dc.subjectBlock-based principal component analysisen
dc.subjectNon-rigid image registrationen
dc.subjectMedical imagesen
dc.subjectDeep learningen
dc.subjectPrincipal component analysisen
dc.titleRegistro não-rígido de imagens médicas usando block-based principal component analysis como camada de poolingpt
dc.title.alternativeNon-rigid registration of medical images using block-based principal component analysis as pooling layeren
dc.typeDissertação de mestrado
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Geociências e Ciências Exatas, Rio Claropt
unesp.embargoOnlinept
unesp.examinationboard.typeBanca públicapt
unesp.graduateProgramCiência da Computação - FC/FCT/IBILCE/IGCE 33004153073P2pt
unesp.knowledgeAreaComputação aplicadapt
unesp.researchAreaInteligência computacionalpt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
pinheiro-junior_u_me_rcla.pdf
Tamanho:
12.76 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
3.01 KB
Formato:
Item-specific license agreed upon to submission
Descrição: