Test-retest reliability of a 3-min isokinetic all-out test using two different cadences

dc.contributor.authorde Lucas, Ricardo Dantas
dc.contributor.authorGreco, Camila Coelho
dc.contributor.authorDekerle, Jeanne
dc.contributor.authorCaritá, Renato Aparecido Corrêa
dc.contributor.authorGuglielmo, Luiz Guilherme Antonacci
dc.contributor.authorDenadai, Benedito Sérgio
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:30:52Z
dc.date.available2014-05-27T11:30:52Z
dc.date.issued2013-10-17
dc.description.abstractObjectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.en
dc.identifierhttp://dx.doi.org/10.1016/j.jsams.2013.09.005
dc.identifier.citationJournal of Science and Medicine in Sport.
dc.identifier.doi10.1016/j.jsams.2013.09.005
dc.identifier.issn1440-2440
dc.identifier.issn1878-1861
dc.identifier.lattes7416129894680689
dc.identifier.lattes1907479250833033
dc.identifier.scopus2-s2.0-84885361764
dc.identifier.urihttp://hdl.handle.net/11449/76877
dc.language.isoeng
dc.relation.ispartofJournal of Science and Medicine in Sport
dc.relation.ispartofjcr3.929
dc.relation.ispartofsjr1,714
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectCycling
dc.subjectEnd-power
dc.subjectPedal rate
dc.subjectPower output profile
dc.titleTest-retest reliability of a 3-min isokinetic all-out test using two different cadencesen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
unesp.author.lattes7416129894680689[2]
unesp.author.lattes1907479250833033[6]
unesp.author.orcid0000-0003-0775-1889[6]
unesp.author.orcid0000-0002-7611-9759[2]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Biociências, Rio Claropt

Arquivos