COMPARING LQG/LTR AND THE SORE TECHNIQUES FOR HYBRID FULLY-CONNECTED PLL NETWORK CONTROL

dc.contributor.authorBueno, Atila Madureira [UNESP]
dc.contributor.authorTusset, Angelo Marcelo
dc.contributor.authorFerruzzo Correa, Diego Paolo
dc.contributor.authorCastilho Piqueira, Jose Roberto
dc.contributor.authorBalthazar, Jose Manoel [UNESP]
dc.contributor.authorASME
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionFed Tech Univ Parana
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2019-10-04T12:29:51Z
dc.date.available2019-10-04T12:29:51Z
dc.date.issued2014-01-01
dc.description.abstractSynchronization plays an important role in telecommunication systems and integrated circuits. The Master-Slave is a commonly used strategy for clock signal distribution. However, due to the wireless networks development and the higher operation frequency of integrated circuits, the Mutually-Connected clock distribution strategies are becoming important, and the Fully-Connected strategy appears as a convenient engineering solution. The main drawback of the Fully-Connected architecture is the definition of control algorithms that assure the stability of the network sinchronization. In hybrid synchronization techniques groups of nodes synchronized by the Fully-Connected architecture are synchronized with network master clocks by using the Master-Slave tecnique. In this arrangement, if a route of clock signal distribution becomes inoperative, the group of Fully-Connected nodes retain for some time the original phase and frequency received from the network. The Fully-Connected architecture complexity imposes difficulties to satisfy both stability and performance requirements in the control system design. For that reason the multi-variable LQG/LTR and the SDRE control techniques are applied in order to fulfill both stability and performance requirements. The performance of both techniques are compared, and the results seems to confirm the improvement in the transient response and in the precision of the clock distribution process.en
dc.description.affiliationUNESP, Sao Paulo State Univ, Autom & Control Eng Dept, BR-18087180 Sorocaba, SP, Brazil
dc.description.affiliationFed Tech Univ Parana, Dept Elect, Ponta Grossa, Parana, Brazil
dc.description.affiliationUniv Sao Paulo, Telec & Control Eng Dept, Polytech Sch, BR-05508 Sao Paulo, Brazil
dc.description.affiliationUNESP, Sao Paulo State Univ, Dep Stat Appl Math & Comput, Rio Claro, SP, Brazil
dc.description.affiliationUnespUNESP, Sao Paulo State Univ, Autom & Control Eng Dept, BR-18087180 Sorocaba, SP, Brazil
dc.description.affiliationUnespUNESP, Sao Paulo State Univ, Dep Stat Appl Math & Comput, Rio Claro, SP, Brazil
dc.format.extent7
dc.identifier.citationProceedings Of The Asme International Design Engineering Technical Conferences And Computers And Information In Engineering Conference, 2013, Vol 8. New York: Amer Soc Mechanical Engineers, 7 p., 2014.
dc.identifier.urihttp://hdl.handle.net/11449/184771
dc.identifier.wosWOS:000362796100038
dc.language.isoeng
dc.publisherAmer Soc Mechanical Engineers
dc.relation.ispartofProceedings Of The Asme International Design Engineering Technical Conferences And Computers And Information In Engineering Conference, 2013, Vol 8
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.titleCOMPARING LQG/LTR AND THE SORE TECHNIQUES FOR HYBRID FULLY-CONNECTED PLL NETWORK CONTROLen
dc.typeTrabalho apresentado em evento
dcterms.rightsHolderAmer Soc Mechanical Engineers
unesp.author.lattes7416585768192991[1]
unesp.author.orcid0000-0002-1113-3330[1]

Arquivos