Analytical procedures for cadmium determination in facial make-up samples by graphite furnace AAS

dc.contributor.authorBarros, Ariane Isis [UNESP]
dc.contributor.authorMiranda, Kelber [UNESP]
dc.contributor.authorFerreira, Edilene Cristina [UNESP]
dc.contributor.authorNeto, José Anchieta Gomes [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-10-21T20:22:12Z
dc.date.available2015-10-21T20:22:12Z
dc.date.issued2015-03-01
dc.description.abstractThis paper describes the development of analytical procedures for the determination of cadmium in facial make-up based on line-source graphite furnace AAS (LS-GFAAS) and direct solid sampling (DSS) coupled to a high-resolution continuum source graphite furnace AAS (HR-CS-GFAAS). Eye shadow, blush, and compact powder samples were analyzed by LS-GFAAS after microwave-assisted digestion with an HNO3/H2O2/HF mixture. Use of boric acid to eliminate HF from the digests was not feasible due to precipitation. Ammonium hydroxide was then dispensed into the graphite platform to eliminate HF and reduce digest acidity. The DSS HR-CS GFAAS procedure did not require any previous treatment. Both proposed procedures were validated using a certified reference material. Then, cadmium was determined in six facial make-up samples by LS-GFAAS and DSS HR-CS GFAAS with calibration against aqueous standard solutions. A paired t-test at a 95% confidence level showed that the DSS HR-CS GFAAS procedure enabled the achievement of similar results as those obtained by LS-GFAAS after acid digestion. The precision, expressed as the relative standard deviation, varied from 2.0 to 9.1% (LS-GFAAS) and from 1.0 to 11.1% (DSS HR-CS GFAAS). The DSS HR-CS GFAAS procedure was then applied for the determination of cadmium in 30 blush samples and 130 eye shadow samples of different brands and colors. The cadmium concentration varied from 12 to 111 mu g kg(-1) in the blush samples and from 5.1 to 198 mu g kg(-1) in the eye shadow samples.en
dc.description.affiliationUnespUniversidade Estadual Paulista, Departamento de Química Analítica, Instituto de Química de Araraquara
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIdFAPESP: 14/12595-1
dc.format.extent102-107
dc.identifierhttp://apps.webofknowledge.com/full_record.do?product=UA&search_mode=GeneralSearch&qid=1&SID=2AxdKKRkjUBJl514Kcl&page=1&doc=1
dc.identifier.citationAtomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 36, n. 2, p. 102-107, 2015.
dc.identifier.issn0195-5373
dc.identifier.lattes9756414550075565
dc.identifier.urihttp://hdl.handle.net/11449/129102
dc.identifier.wosWOS:000352829000006
dc.language.isoeng
dc.publisherPerkin-elmer Corp
dc.relation.ispartofAtomic Spectroscopy
dc.relation.ispartofjcr1.123
dc.relation.ispartofsjr0,327
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleAnalytical procedures for cadmium determination in facial make-up samples by graphite furnace AASen
dc.typeArtigo
dcterms.rightsHolderPerkin-elmer Corp
unesp.author.lattes9756414550075565
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Química, Araraquarapt