Publicação: Evaluation of Lines of Phosphorus and Potassium by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Liquid Fertilizer Analysis
dc.contributor.author | Ferreira, Roberta Borges [UNESP] | |
dc.contributor.author | Oliveira, Silvana Ruella [UNESP] | |
dc.contributor.author | Franzini, Vanessa Pezza [UNESP] | |
dc.contributor.author | Virgilio, Alex [UNESP] | |
dc.contributor.author | Raposo Junior, Jorge Luiz [UNESP] | |
dc.contributor.author | Gomes Neto, José Anchieta [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T14:19:12Z | |
dc.date.available | 2014-05-20T14:19:12Z | |
dc.date.issued | 2011-03-01 | |
dc.description.abstract | The usefulness of the side pixel registration approach and molecular absorption was investigated for the determination of phosphorus (P) and potassium (K) in liquid fertilizers by high-resolution continuum source flame atomic absorption spectrometry.The phosphorus oxide (PO) lines at 246.400 nm, 247.620 nm, 247.780 nm, 324.616 nm, and 327.040 nm were evaluated. The influence of side pixel registration to extend the linear working range was also investigated by measuring at wings (404.402 nm, 404.406 nm, 404.410 nm, 404.418 nm, 404.422 nm and 404.426 nm) of the secondary line for K at 404.414 nm. For the lines 327.040 mm and 404.422 nm, analytical curves in the 100-5000 mg L-1 and 50-1000 mg L-1 ranges were obtained with linear correlations better than 0.999 and 0.995, respectively.The proposed method was applied to six liquid fertilizer samples. The found concentrations for K and P were in agreement with those obtained by inductively coupled plasma optical emission spectrometry (ICP-OES), spectrophotometry, and flame atomic emission spectrometry at the 95% confidence level. | en |
dc.description.affiliation | UNESP Univ Estadual Paulista, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | UNESP Univ Estadual Paulista, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description.sponsorshipId | CNPq: 300600/2009-7 | |
dc.format.extent | 56-61 | |
dc.identifier | http://jglobal.jst.go.jp/public/20090422/201202230103386562 | |
dc.identifier.citation | Atomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 32, n. 2, p. 56-61, 2011. | |
dc.identifier.issn | 0195-5373 | |
dc.identifier.lattes | 8708735699846578 | |
dc.identifier.uri | http://hdl.handle.net/11449/25787 | |
dc.identifier.wos | WOS:000289743800002 | |
dc.language.iso | eng | |
dc.publisher | Perkin-elmer Corp | |
dc.relation.ispartof | Atomic Spectroscopy | |
dc.relation.ispartofjcr | 1.123 | |
dc.relation.ispartofsjr | 0,327 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | Evaluation of Lines of Phosphorus and Potassium by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Liquid Fertilizer Analysis | en |
dc.type | Artigo | |
dcterms.rightsHolder | Perkin-elmer Corp | |
dspace.entity.type | Publication | |
unesp.author.lattes | 8708735699846578 | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: