Validação do analisador hematológico automático BC-2800 VET® para realização de hemogramas de muares

dc.contributor.advisorMendes, Luiz Cláudio Nogueira [UNESP]
dc.contributor.authorMiranda, Gislaine Matias Dantas [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-10-06T13:03:14Z
dc.date.available2015-10-06T13:03:14Z
dc.date.issued2014-02-28
dc.description.abstractIn this study the values of complete blood counts performed in 30 mules aged 4 and 8, obtained by using an automated hematology analyzer and the manual blood counts were compared. The results showed that the correlation between the two methods were considered good since the bias (mean difference) was small, and the confidence intervals of 95 % for the bias showed up narrow and only one outlier was observed for erythrocytes, monocytes and granulocytes (no value fell outside the limits of agreement [bias ± 2 standard deviations]). There was no significant difference in the values of erythrocytes, hemoglobin, leukocytes and granulocytes. The average values obtained from monocytes by an automatic cell counter were significantly higher than those obtained by the manual method. The results also showed a positive bias for hematocrit and no bias was detected in erythrocytes, hemoglobin, leukocytes, granulocytes and lymphocytes. Good agreement between the results obtained by the two methods for erythrocytes, hemoglobin, leukocytes, granulocytes, lymphocytes and monocytes was observed in this age group. Can the automated hematology analyzer BC-2800Vet® be used to perform complete blood counts in mulesen
dc.format.extent35 f.
dc.identifier.aleph000849287
dc.identifier.capes33004021075P8
dc.identifier.citationMIRANDA, Gislaine Matias Dantas. Validação do analisador hematológico automático BC-2800 VET® para realização de hemogramas de muares. 2014. 35 f. , 2014.
dc.identifier.filehttp://www.athena.biblioteca.unesp.br/exlibris/bd/cathedra/16-09-2015/000849287.pdf
dc.identifier.lattes2232625970712015
dc.identifier.urihttp://hdl.handle.net/11449/128089
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso aberto
dc.sourceAleph
dc.subjectMuarpt
dc.subjectGranulomapt
dc.subjectEstatistica - Analisept
dc.subjectMedia (Matematica)pt
dc.subjectSaude animalpt
dc.subjectHematology analyzerpt
dc.titleValidação do analisador hematológico automático BC-2800 VET® para realização de hemogramas de muarespt
dc.typeDissertação de mestrado
unesp.advisor.lattes2232625970712015
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina Veterinária, Araçatubapt
unesp.graduateProgramCiência Animal - FMVApt
unesp.knowledgeAreaFisiopatologia médica e cirurgicapt
unesp.researchAreaFisiopatologia médica e cirurgica de grandes animaispt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
000849287.pdf
Tamanho:
224.87 KB
Formato:
Adobe Portable Document Format