Evaluation of low intensity laser's action on silicone mammary implant pseudocapsules in rats

dc.contributor.authorPalhares Neto, Aristides Augusto [UNESP]
dc.contributor.authorSchellini, Silvana Artioli [UNESP]
dc.contributor.authorPellizzon, Claudia Helena [UNESP]
dc.contributor.authorPadovani, Carlos Roberto [UNESP]
dc.contributor.authorDorsa, Patrícia [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:36:30Z
dc.date.available2014-05-20T13:36:30Z
dc.date.issued2009-02-01
dc.description.abstractOBJETIVO: Avaliar o efeito do laser de baixa intensidade sobre a contração da pseudocápsula que ocorre ao redor de implantes de silicone. MÉTODOS: 60 ratos machos divididos em dois grupos receberam implante de silicone. Grupo I: implante no subcutâneo da região dorsal, sem tratamento após a cirurgia; Grupo II: animais receberam sete sessões de irradiação com laser de baixa intensidade após o implante. Trinta, 60 e 180 dias após a cirurgia, foi feita a tonometria dos implantes, em seguida, os animais foram sacrificados, removendo-se o material de estudo que foi preparado para exame histológico, avaliando-se morfometricamente a espessura da pseudocápsula e a reação inflamatória. A análise estatistica pela técnica da Análise de Variância e Teste de Tukey (P<0.0 5). RESULTADOS: Pressões significativamente menores foram encontradas nos animais do grupo Grupo II. O estudo histológico não mostrou diferença significativa entre os grupos, destacando-se apenas maior quantidade de vasos intumescidos no Grupo II. A espessura da pseudocápsula foi menor no Grupo II. CONCLUSÃO: O laser de baixa intensidade altera o processo de reparação tecidual ao redor dos implantes, sugerindo que o mesmo possa ser útil para a modelação das contraturas que se estabelecem ao redor dos implantes de silicone.pt
dc.description.abstractPURPOSE: To evaluate the effect of low intensity laser on the pseudocapsula contraction that occurs around silicone implants. METHODS: 60 male rats divided in two experimental groups received a silicone implant in the subcutaneous of the dorsal region. Group I: animals received implants in the subcutaneous dorsal region and did not receive any treatment; Group II: animals received seven irradiation sessions with low intensity laser after they had received subcutaneous implants. Thirty, 60 and 180 days after the surgery, tonometric evaluation of the implants was conducted. After that, the animals were sacrificed, study material was removed and prepared for histological examination. The thickness of the pseudocapsule and the inflammatory reaction were morphometrically quantified. Data obtained were statistically analyzed using the Variance method, and Tukey's Test(P<0.0 5). RESULTS: Group II animals had significant lower pressure. The histological study did not show a significant difference between the groups, but only a higher number of swollen vessels in Group II. The thickness of pseudocapsule around Group II's implants lower than in Group I. CONCLUSION: The low intensity laser modify tissue's reparation process around the implants suggesting it may be useful to model contractures that are formed around silicone implants.en
dc.description.affiliationUNESP Department of Surgery and Orthopedic
dc.description.affiliationUNESP Botucatu Faculty of Medicine Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery
dc.description.affiliationUNESP Botucatu Biosciences Institute
dc.description.affiliationUNESP Botucatu Faculty of Medicine Department of Surgery and Orthopedic
dc.description.affiliationUnespUNESP Department of Surgery and Orthopedic
dc.description.affiliationUnespUNESP Botucatu Faculty of Medicine Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery
dc.description.affiliationUnespUNESP Botucatu Biosciences Institute
dc.description.affiliationUnespUNESP Botucatu Faculty of Medicine Department of Surgery and Orthopedic
dc.format.extent7-12
dc.identifierhttp://dx.doi.org/10.1590/S0102-86502009000100003
dc.identifier.citationActa Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 24, n. 1, p. 7-12, 2009.
dc.identifier.doi10.1590/S0102-86502009000100003
dc.identifier.fileS0102-86502009000100003.pdf
dc.identifier.issn0102-8650
dc.identifier.lattes9420249100835492
dc.identifier.lattes0019393779801069
dc.identifier.orcid0000-0002-4494-4180
dc.identifier.scieloS0102-86502009000100003
dc.identifier.urihttp://hdl.handle.net/11449/12564
dc.identifier.wosWOS:000264560300002
dc.language.isoeng
dc.publisherSociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.relation.ispartofActa Cirúrgica Brasileira
dc.relation.ispartofjcr0.933
dc.relation.ispartofsjr0,395
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectImplantes de Mamapt
dc.subjectTerapia a Laser de Baixa Intensidadept
dc.subjectSiliconespt
dc.subjectRatspt
dc.subjectBreast Implantsen
dc.subjectLaser Therapy, Low-Levelen
dc.subjectSiliconesen
dc.subjectRatsen
dc.titleEvaluation of low intensity laser's action on silicone mammary implant pseudocapsules in ratsen
dc.title.alternativeAvaliação do laser de baixa intensidade sobre a pseudocápsula de implantes mamários de silicone em ratospt
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/acb/paboutj.htm
dcterms.rightsHolderActa Cirúrgica Brasileira
unesp.author.lattes9420249100835492
unesp.author.lattes8588587034751584[1]
unesp.author.lattes8727897080522289[4]
unesp.author.lattes0019393779801069[3]
unesp.author.orcid0000-0002-4494-4180[3]
unesp.author.orcid0000-0002-7719-9682[4]
unesp.author.orcid0000-0002-6938-1230[2]
unesp.author.orcid0000-0002-3484-862X[1]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatupt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0102-86502009000100003.pdf
Tamanho:
1.88 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: