Estudo in vivo e in vitro com e sem termociclagem, da resistência ao cisalhamento de braquetes colados com fonte de luz halógena

dc.contributor.authorPenido, Sérgio Milton Martins de Oliveira [UNESP]
dc.contributor.authorPenido, Cláudia Valéria de Sousa Resende
dc.contributor.authorSantos-Pinto, Ary dos [UNESP]
dc.contributor.authorSakima, Tatsuko [UNESP]
dc.contributor.authorFontana, Carla Raquel [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionPontifícia Universidade Católica de Minas Gerais (PUC-Minas)
dc.date.accessioned2013-09-30T18:31:36Z
dc.date.accessioned2014-05-20T13:45:02Z
dc.date.available2013-09-30T18:31:36Z
dc.date.available2014-05-20T13:45:02Z
dc.date.issued2008-06-01
dc.description.abstractOBJETIVO: avaliar a resistência de braquetes metálicos colados em dentes humanos com resina polimerizada com luz halógena por meio de ensaios mecânicos de cisalhamento. METODOLOGIA: para este estudo foram realizados ensaios in vivo com dinamômetro portátil digital e in vitro com máquina de ensaios mecânicos universal com e sem termociclagem, complementado pelo Índice de Adesivo Remanescente (IAR). Braquetes Edgewise Standard (Abzil) foram colados utilizando adesivo Transbond Plus Self Etching Primer (SEP) e Resina Transbond XT. Foram formados 3 grupos com 10 dentes em cada um deles. No GI os braquetes foram colados nos segundos pré-molares dos pacientes. Nos GII e GIII utilizaram-se primeiros pré-molares extraídos por motivos ortodônticos. Os ensaios mecânicos do GI foram realizados 24 horas após a polimerização diretamente na boca dos pacientes com dinamômetro portátil digital. No GII os corpos-de-prova foram armazenados em água destilada e levados à estufa a 37ºC durante 24 horas e, posteriormente, submetidos à termociclagem, com 1000 ciclos a 5 e 55ºC. No GIII os corpos-de-prova foram armazenados em água destilada em temperatura ambiente por 24 horas e posteriormente submetidos aos ensaios mecânicos. RESULTADOS: os valores médios da resistência ao cisalhamento em Megapascal foram de: GI = 4,39; GII = 7,11 e GIII = 7,35. Após a descolagem foram realizadas fotografias das áreas de colagem, tanto dos dentes submetidos a testes in vivo quanto in vitro e ampliadas 5x para facilitar a visualização. As imagens obtidas foram analisadas, classificadas de acordo com o IAR e, por meio de gráficos de dispersão, foi verificada a relação entre a resistência ao cisalhamento e este índice. CONCLUSÃO: a média dos ensaios mecânicos realizados in vivo foi estatisticamente menor em relação aos ensaios in vitro. Não houve diferenças na resistência ao cisalhamento in vitro entre o grupo termociclado e o não-termociclado. Não houve relação entre tensão de ruptura e tipo de falha.pt
dc.description.abstractOBJECTIVE: The purpose of this research was to assess the strength of metallic brackets bonded to human teeth, with lightcuring resin with halogen light, by means of mechanical tests of shear bond strength. METHODS: In vivo tests with a portable digital dynamometer and in vitro tests with Universal testing machine were performed, with and without thermocycling, complemented by Adhesive Remaining Index (ARI). Edgewise standard brackets (Abzil) were bonded using Transbond Plus Self Etching Primer (SEP) and Transbond XT resin. Three groups of ten teeth each have been formed. In GI the brackets were bonded to second premolars in the patients mouths. In GII and GIII the brackets were bonded to first premolars extracted for orthodontic reasons. The mechanical tests of GI were performed 24 hours after the polymerization, directly in the patients mouths with a portable digital dynamometer. In GII the specimens were stored in distilled water and taken to sterilizer at 37ºC for 24 hours and afterwards, submitted to thermocycling with 1000 cycles at 5 and 55º C. In GIII the specimens were stored in distilled water at room temperature for 24 hours, and then submitted to mechanical tests. RESULTS: The average values of the shear strength in Megapascal were: GI=4.39; GII=7.11 and GIII=7.35. Pictures of the bonding areas in both in vivo and in vitro samples were taken after the tests and they were amplified 5 times to be better visualized. The images obtained were analyzed, classified according to IAR and it was verified, by means of dispersion graphs, the relation between the shear bond strength and this index. CONCLUSION: The average of the in vivo mechanical tests was statistically lower than the in vitro tests. There were no differences in the in vitro shear bond strength between the thermocycled and non-thermocycled groups. There was no relation between shearing stress and kind of failure.en
dc.description.affiliationUNESP Faculdade de Odontologia de Araraquara
dc.description.affiliationPUC Minas Faculdade de Odontologia
dc.description.affiliationUNESP Faculdade de Odontologia de Araraquara Departamento de Clínica Infantil
dc.description.affiliationUnespUNESP Faculdade de Odontologia de Araraquara
dc.description.affiliationUnespUNESP Faculdade de Odontologia de Araraquara Departamento de Clínica Infantil
dc.format.extent66-76
dc.identifierhttp://dx.doi.org/10.1590/S1415-54192008000300009
dc.identifier.citationRevista Dental Press de Ortodontia e Ortopedia Facial. Dental Press Editora, v. 13, n. 3, p. 66-76, 2008.
dc.identifier.doi10.1590/S1415-54192008000300009
dc.identifier.fileS1415-54192008000300009.pdf
dc.identifier.issn1415-5419
dc.identifier.scieloS1415-54192008000300009
dc.identifier.urihttp://hdl.handle.net/11449/15803
dc.language.isopor
dc.publisherDental Press Editora
dc.relation.ispartofRevista Dental Press de Ortodontia e Ortopedia Facial
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectResistência ao cisalhamentopt
dc.subjectLuz halógenapt
dc.subjectMáquina universal de ensaios mecânicospt
dc.subjectTermociclagempt
dc.subjectTensiômetro portátil digitalpt
dc.subjectShear bond strengthen
dc.subjectLighten
dc.subjectUniversal testing machineen
dc.subjectThermocyclingen
dc.subjectPortable digital debonding deviceen
dc.titleEstudo in vivo e in vitro com e sem termociclagem, da resistência ao cisalhamento de braquetes colados com fonte de luz halógenapt
dc.title.alternativeIn vivo and in vitro study, with or without thermocycling, of shear bond strength of brackets bonded with halogen lighten
dc.typeArtigo
unesp.author.lattes6562540057111580[3]
unesp.author.lattes5168319315634298[5]
unesp.author.orcid0000-0003-3355-0001[3]
unesp.author.orcid0000-0002-9135-3690[5]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquarapt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1415-54192008000300009.pdf
Tamanho:
209.54 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: