Non-newtonian heat transfer on a plate heat exchanger with generalized configurations
dc.contributor.author | Carezzato, Alessandra | |
dc.contributor.author | Alcantara, Maria R. | |
dc.contributor.author | Telis-Romero, Javier | |
dc.contributor.author | Tadini, Carmen C. | |
dc.contributor.author | Gut, Jorge A. W. | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T15:21:50Z | |
dc.date.available | 2014-05-20T15:21:50Z | |
dc.date.issued | 2007-01-01 | |
dc.description.abstract | For the configuration optimization of plate heat exchangers (PHEs), the mathematical models for heat transfer and pressure drop must be valid for a wide range of operational conditions of all configurations of the exchanger or the design results may be compromised. In this investigation, the thermal model of a PHE is adjusted to fit experimental data obtained from non-Newtonian heat transfer for eight different configurations, using carboxymethylcellulose solutions (CMC) as test fluid. Although it is possible to successfully adjust the model parameters, Newtonian and non-Newtonian heat transfer cannot be represented by a single generalized correlation. In addition, the specific heat, thermal conductivity and power-law rheological parameters of CMC solutions were correlated with temperature, over a range compatible with a continuous pasteurization process. | en |
dc.description.affiliation | Univ São Paulo, Escola Politecn, Dept Chem Engn, BR-05424970 São Paulo, Brazil | |
dc.description.affiliation | Univ São Paulo, Inst Chem, Dept Fundamental Chem, São Paulo, Brazil | |
dc.description.affiliation | Univ Estadual Paulista, Dept Food Engn & Technol, Sao Jose do Rio Preto, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Dept Food Engn & Technol, Sao Jose do Rio Preto, Brazil | |
dc.format.extent | 21-26 | |
dc.identifier | http://dx.doi.org/10.1002/ceat.200600294 | |
dc.identifier.citation | Chemical Engineering & Technology. Weinheim: Wiley-v C H Verlag Gmbh, v. 30, n. 1, p. 21-26, 2007. | |
dc.identifier.doi | 10.1002/ceat.200600294 | |
dc.identifier.issn | 0930-7516 | |
dc.identifier.uri | http://hdl.handle.net/11449/32931 | |
dc.identifier.wos | WOS:000243622100003 | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell | |
dc.relation.ispartof | Chemical Engineering & Technology | |
dc.relation.ispartofjcr | 1.588 | |
dc.relation.ispartofsjr | 0,493 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | heat exchangers | pt |
dc.subject | non-Newtonian fluids | pt |
dc.subject | process modeling | pt |
dc.title | Non-newtonian heat transfer on a plate heat exchanger with generalized configurations | en |
dc.type | Artigo | |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dcterms.rightsHolder | Wiley-Blackwell | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Biociências Letras e Ciências Exatas, São José do Rio Preto | pt |
unesp.department | Engenharia e Tecnologia de Alimentos - IBILCE | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: