Using an Electrochemical MIP Sensor for Selective Determination of 1-Naphthol in Oilfield Produced Water
Nenhuma Miniatura disponível
Data
2021-05-01
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Tipo
Artigo
Direito de acesso
Resumo
A molecularly imprinted polymer (MIP) sensor was successfully constructed on glassy carbon electrode for the determination of 1-naphthol (1-Nph). The sensor was constructed by electropolymerization on bare GCE in the presence of the target molecule. The recognition of 1-Nph was conducted indirectly using [Fe(CN)6]3−/4− as redox probe. The MIP sensor presented wide linear working range and limit of detection of 1.5×10−9 mol L−1. The MIP sensor was applied for the determination of 1-Nph in oilfield produced water. The results obtained showed good selectivity and sensitivity of the proposed sensor in terms of 1-Nph quantification.
Descrição
Idioma
Inglês
Como citar
Electroanalysis, v. 33, n. 5, p. 1346-1355, 2021.