Publicação:
An approach of optimal sensitivity applied in the tertiary loop of the automatic generation control

dc.contributor.authorBelati, Edmarcio A.
dc.contributor.authorAlves, Dilson A. [UNESP]
dc.contributor.authorda Costa, Geraldo R. M.
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionSENAI
dc.date.accessioned2014-05-20T15:30:45Z
dc.date.available2014-05-20T15:30:45Z
dc.date.issued2008-09-01
dc.description.abstractThis paper proposes an approach of optimal sensitivity applied in the tertiary loop of the automatic generation control. The approach is based on the theorem of non-linear perturbation. From an optimal operation point obtained by an optimal power flow a new optimal operation point is directly determined after a perturbation, i.e., without the necessity of an iterative process. This new optimal operation point satisfies the constraints of the problem for small perturbation in the loads. The participation factors and the voltage set point of the automatic voltage regulators (AVR) of the generators are determined by the technique of optimal sensitivity, considering the effects of the active power losses minimization and the network constraints. The participation factors and voltage set point of the generators are supplied directly to a computational program of dynamic simulation of the automatic generation control, named by power sensitivity mode. Test results are presented to show the good performance of this approach. (C) 2008 Elsevier B.V. All rights reserved.en
dc.description.affiliationUniv São Paulo, EESC, Dept Elect Engn, BR-05508 São Paulo, Brazil
dc.description.affiliationUniv São Paulo, UNESP, FEIS, Dept Elect Engn, BR-05508 São Paulo, Brazil
dc.description.affiliationSENAI, CIMATEC, Salvador, BA, Brazil
dc.description.affiliationUnespUniv São Paulo, UNESP, FEIS, Dept Elect Engn, BR-05508 São Paulo, Brazil
dc.format.extent1553-1560
dc.identifierhttp://dx.doi.org/10.1016/j.epsr.2008.01.017
dc.identifier.citationElectric Power Systems Research. Lausanne: Elsevier B.V. Sa, v. 78, n. 9, p. 1553-1560, 2008.
dc.identifier.doi10.1016/j.epsr.2008.01.017
dc.identifier.issn0378-7796
dc.identifier.urihttp://hdl.handle.net/11449/40064
dc.identifier.wosWOS:000257619800009
dc.language.isoeng
dc.publisherElsevier B.V. Sa
dc.relation.ispartofElectric Power Systems Research
dc.relation.ispartofjcr2.856
dc.relation.ispartofsjr1,048
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectautomatic generation controlen
dc.subjectload frequency controlen
dc.subjectarea control erroren
dc.subjectoptimal power flowen
dc.subjectactive power loss minimizationen
dc.titleAn approach of optimal sensitivity applied in the tertiary loop of the automatic generation controlen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V. Sa
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: