Effect of Ce(III) and Ce(IV) ions on the structure and active protection of PMMA-silica coatings on AA7075 alloy
| dc.contributor.author | Trentin, A. [UNESP] | |
| dc.contributor.author | Harb, S. V. [UNESP] | |
| dc.contributor.author | Uvida, M. C. [UNESP] | |
| dc.contributor.author | Marcoen, K. | |
| dc.contributor.author | Pulcinelli, S. H. [UNESP] | |
| dc.contributor.author | Santilli, C. V. [UNESP] | |
| dc.contributor.author | Terryn, H. | |
| dc.contributor.author | Hauffman, T. | |
| dc.contributor.author | Hammer, P. [UNESP] | |
| dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
| dc.contributor.institution | Vrije Universiteit Brussel | |
| dc.date.accessioned | 2022-05-01T04:55:59Z | |
| dc.date.available | 2022-05-01T04:55:59Z | |
| dc.date.issued | 2021-08-15 | |
| dc.description.abstract | This work investigates the effect of Ce(III) and Ce(IV) additives on the structure and anti-corrosion properties of poly(methyl methacrylate) (PMMA)-silica coatings on AA7075 aluminium alloy. The results revealed that intermediate Ce(IV) loadings (500 and 1000 ppm) result in a dense hybrid network with a less defective polymeric phase, extending the service time of AA7075 up to 835 days in 3.5% NaCl. Although both additives provide long-term protection, the self-healing ability was observed only for Ce(IV) addition, favoured by the formation of oxides/hydroxides at pH∼3. These properties make the 4 μm-thick PMMA-silica-Ce(IV) coatings very interesting for chromium-free protection technologies. | en |
| dc.description.affiliation | Sao Paulo State University Institute of Chemistry | |
| dc.description.affiliation | Vrije Universiteit Brussel Department of Electrochemical and Surface Engineering, Pleinlaan 2 | |
| dc.description.affiliationUnesp | Sao Paulo State University Institute of Chemistry | |
| dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
| dc.description.sponsorshipId | FAPESP: 2014/12182-9 | |
| dc.description.sponsorshipId | FAPESP: 2015/09342-7 | |
| dc.description.sponsorshipId | FAPESP: 2015/11907-2 | |
| dc.identifier | http://dx.doi.org/10.1016/j.corsci.2021.109581 | |
| dc.identifier.citation | Corrosion Science, v. 189. | |
| dc.identifier.doi | 10.1016/j.corsci.2021.109581 | |
| dc.identifier.issn | 0010-938X | |
| dc.identifier.scopus | 2-s2.0-85107299694 | |
| dc.identifier.uri | http://hdl.handle.net/11449/233147 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Corrosion Science | |
| dc.source | Scopus | |
| dc.subject | Aluminium alloy | |
| dc.subject | EIS | |
| dc.subject | Inhibition | |
| dc.subject | Intermetallics | |
| dc.subject | Organic coatings | |
| dc.subject | SIMS | |
| dc.title | Effect of Ce(III) and Ce(IV) ions on the structure and active protection of PMMA-silica coatings on AA7075 alloy | en |
| dc.type | Artigo | pt |
| dspace.entity.type | Publication | |
| relation.isOrgUnitOfPublication | bc74a1ce-4c4c-4dad-8378-83962d76c4fd | |
| relation.isOrgUnitOfPublication.latestForDiscovery | bc74a1ce-4c4c-4dad-8378-83962d76c4fd | |
| unesp.author.orcid | 0000-0001-7148-4661[2] | |
| unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
| unesp.department | Físico-Química - IQAR | pt |