Publicação: A NOVEL SINGLE-PHASE HPF HYBRID RECTIFIER SUITABLE FOR FRONT-END TROLLEYBUS SYSTEMS
dc.contributor.author | Freitas, Luiz C. G. | |
dc.contributor.author | Lima, Gustavo B. | |
dc.contributor.author | Goncalves, Flavio A. S. [UNESP] | |
dc.contributor.author | Melo, Guilherme A. [UNESP] | |
dc.contributor.author | Canesin, Carlos A. [UNESP] | |
dc.contributor.author | Freitas, Luiz C. de | |
dc.contributor.author | IEEE | |
dc.contributor.institution | Universidade Federal de Uberlândia (UFU) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2020-12-10T22:02:03Z | |
dc.date.available | 2020-12-10T22:02:03Z | |
dc.date.issued | 2009-01-01 | |
dc.description.abstract | This paper proposal presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THD1), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THD1, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results of a 15kW prototype are also presented in this paper. | en |
dc.description.affiliation | Univ Fed Uberlandia, Fac Engn Eletr FEELT, NUPEP, BR-38400902 Uberlandia, MG, Brazil | |
dc.description.affiliation | Univ Estadual Paulista UNESP, FEIS, LEP, BR-15385000 Ilha Solteira, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista UNESP, FEIS, LEP, BR-15385000 Ilha Solteira, SP, Brazil | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG) | |
dc.description.sponsorship | ANEEL-AES Eletropaulo Metropolitana Eletricidade de Sao Paulo S.A. In addition | |
dc.format.extent | 112-+ | |
dc.identifier.citation | 2009 Brazilian Power Electronics Conference, Vols 1 And 2. New York: Ieee, p. 112-+, 2009. | |
dc.identifier.uri | http://hdl.handle.net/11449/197396 | |
dc.identifier.wos | WOS:000278416900017 | |
dc.language.iso | eng | |
dc.publisher | Ieee | |
dc.relation.ispartof | 2009 Brazilian Power Electronics Conference, Vols 1 And 2 | |
dc.source | Web of Science | |
dc.subject | Power Factor Correction | |
dc.subject | Hybrid Rectifiers | |
dc.subject | Urban Electrical Transportation Systems | |
dc.subject | Electrical Vehicles | |
dc.subject | Trolleybus | |
dc.title | A NOVEL SINGLE-PHASE HPF HYBRID RECTIFIER SUITABLE FOR FRONT-END TROLLEYBUS SYSTEMS | en |
dc.type | Trabalho apresentado em evento | |
dcterms.license | http://www.ieee.org/publications_standards/publications/rights/rights_policies.html | |
dcterms.rightsHolder | Ieee | |
dspace.entity.type | Publication | |
unesp.author.lattes | 6427185658143370[5] | |
unesp.author.orcid | 0000-0002-1036-2801[1] | |
unesp.author.orcid | 0000-0003-3853-5994[5] | |
unesp.department | Engenharia Elétrica - FEIS | pt |