Logo do repositório
 

Development and application of an electrochemical sensor modified with multi-walled carbon nanotubes and graphene oxide for the sensitive and selective detection of tetracycline

dc.contributor.authorWong, Ademar [UNESP]
dc.contributor.authorScontri, Mateus [UNESP]
dc.contributor.authorMateron, Elsa Maria [UNESP]
dc.contributor.authorLanza, Marcos R.V.
dc.contributor.authorSotomayor, Maria D.P.T. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2018-12-11T16:58:48Z
dc.date.available2018-12-11T16:58:48Z
dc.date.issued2015-11-15
dc.description.abstractIn this work, an electrochemical sensor based on a carbon paste electrode modified with a combination of multi-walled carbon nanotubes functionalized with carboxyl groups (MWCNT-COOH), together with graphene oxide (GO), was developed for the sensitive and selective determination of tetracycline. Electrochemical sensors were constructed using carbon paste modified with 2.6% (w/w) of MWCNT-COOH and 3.1% (w/w) of GO. Under the optimal conditions using adsorptive stripping differential pulse voltammetry (AdSDPV), the sensor showed a linear response for tetracycline concentrations between 2.0 × 10- 5 and 3.1 × 10- 4 mol L- 1, sensitivity of 1.2 × 104 μA L mol- 1, and a detection limit of 3.6 × 10- 7 mol L- 1. The incorporation of GO and MWCNT-COOH in the carbon paste improved the sensitivity, selectivity, and stability of the device. The MWCNT-COOH-GO/CPE sensor was successfully applied for the detection of tetracycline in river water, artificial urine, and pharmaceutical samples, without any need for sample pretreatment. The relative standard deviation (RSD) of the electrochemical measurements was less than 6.0% (n = 3).en
dc.description.affiliationDepartment of Analytical Chemistry Institute of Chemistry State University of São Paulo (UNESP)
dc.description.affiliationInstituto de Química de São Carlos Universidade de São Paulo, P.O. Box 780
dc.description.affiliationUnespDepartment of Analytical Chemistry Institute of Chemistry State University of São Paulo (UNESP)
dc.format.extent250-257
dc.identifierhttp://dx.doi.org/10.1016/j.jelechem.2015.10.001
dc.identifier.citationJournal of Electroanalytical Chemistry, v. 757, p. 250-257.
dc.identifier.doi10.1016/j.jelechem.2015.10.001
dc.identifier.file2-s2.0-84944328693.pdf
dc.identifier.issn1572-6657
dc.identifier.scopus2-s2.0-84944328693
dc.identifier.urihttp://hdl.handle.net/11449/172136
dc.language.isoeng
dc.relation.ispartofJournal of Electroanalytical Chemistry
dc.relation.ispartofsjr0,765
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectAdsorptive stripping differential pulse voltammetry
dc.subjectCarbon nanotube
dc.subjectElectrochemical sensor
dc.subjectGraphene oxide
dc.subjectTetracycline
dc.titleDevelopment and application of an electrochemical sensor modified with multi-walled carbon nanotubes and graphene oxide for the sensitive and selective detection of tetracyclineen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationbc74a1ce-4c4c-4dad-8378-83962d76c4fd
relation.isOrgUnitOfPublication.latestForDiscoverybc74a1ce-4c4c-4dad-8378-83962d76c4fd
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84944328693.pdf
Tamanho:
1.08 MB
Formato:
Adobe Portable Document Format
Descrição: