Heat transfer in packed beds: experimental evaluation of one-phase water flow
Loading...
External sources
External sources
Date
Authors
Advisor
Coadvisor
Graduate program
Undergraduate course
Journal Title
Journal ISSN
Volume Title
Publisher
Brazilian Society of Chemical Engineering
Type
Article
Access right
Acesso aberto

External sources
External sources
Abstract
Experimental heat transfer studies were carried out in 50.8 mm diameter packed beds of glass beads percolated by water and heated from the wall. The tube-to-particle diameter ratio (D/d p) ranged from 1.72 to 13.7 and the water flow rate from 1.1 to 9.9 l/min. Bed heights ranged from 100 mm to 700 mm. The radial temperature was measured above the bed surface by five aligned sheathed thermocouples. Variations in angular temperature were observed, independent of both radial position and particle diameter. Results of repeated tests with the same packing and with repacking did not differ statistically. The radial temperature profile at the bed entrance, measured by a ring-shaped sensor, was uniform except very close to the tube wall.
Description
Keywords
heat transfer, one-phase water flow, radial temperature profile
Language
English
Citation
Brazilian Journal of Chemical Engineering. Brazilian Society of Chemical Engineering, v. 21, n. 1, p. 13-22, 2004.