Logotipo do repositório
 

Publicação:
Confiabilidade inter e intraexaminadores nas mensurações angulares por fotogrametria digital e goniometria

dc.contributor.authorSantos, Jean Douglas Moura dos
dc.contributor.authorOliveira, Marco Antonio de
dc.contributor.authorSilveira, Nelson José Freitas da [UNESP]
dc.contributor.authorCarvalho, Sérgio de Souza
dc.contributor.authorOliveira, Adeno Gonçalves
dc.contributor.institutionUniversidade Estadual do Norte Fluminense
dc.contributor.institutionUniversidade do Vale do Paraíba
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Alfenas (UNIFAL)
dc.contributor.institutionNOVAFAPI Faculdade de Ciências Saúde e Tecnologia
dc.date.accessioned2014-05-20T15:14:18Z
dc.date.available2014-05-20T15:14:18Z
dc.date.issued2011-09-01
dc.description.abstractINTRODUÇÃO: A utilização da fotogrametria computadorizada em prol da goniometria, ou vice-versa, na prática clínica ainda necessita de fundamentações consistentes. OBJETIVOS: Os objetivos deste estudo foram: verificar a confiabilidade inter e intraexaminadores avaliadores na quantificação das medidas angulares obtidas a partir da fotogrametria computadorizada e a goniometria e determinar a confiabilidade paralela entre esses dois diferentes instrumentos de avaliação. MATERIAIS E MÉTODOS: 26 voluntários e 4 examinadores foram utilizados no estudo. A coleta foi realizada em 4 etapas sequenciais: demarcação dos pontos anatômicos de referência, mensuração e registro dos valores goniométricos, captação da imagem do voluntário com os marcadores fixados no corpo e avaliação do registro fotográfico no programa ImageJ. RESULTADOS: O goniômetro é um instrumento confiável na maioria das evidências, porém, a confiabilidade das medições depende principalmente da uniformização dos procedimentos. Considerações metodológicas relativas ao estabelecimento de confiabilidade e padronização da colocação dos marcadores se fazem necessárias, de modo a oferecer opções de avaliação ainda mais confiáveis para a prática clínica. CONCLUSÃO: Ambos os instrumentos são confiáveis e aceitáveis, porém, mais evidências ainda são necessárias para suportar a utilização desses instrumentos, pois poucos pesquisadores têm utilizado o mesmo desenho de estudo, e a comparação dos resultados entre eles muitas vezes são difíceis.pt
dc.description.abstractINTRODUCTION: The use of photogrammetry in support of goniometry or vice versa in clinical practice still requires consistent reasoning. OBJECTIVES: The objectives of this study were to verify the inter and intra-tester reliability evaluators in the quantification of angular measurements obtained from the photogrammetry and goniometry and determine the reliability parallel between these two different assessment tools. MATERIALS and METHODS: 26 volunteers and 4 examiners were used in the study. Data collection was performed in 04 sequential steps: demarcation of anatomical reference points, measurement and recording of goniometric values, image capture volunteer with the markers attached on the body and evaluation of photographic registration in the program ImageJ. RESULTS: The goniometer is a reliable instrument in most of the evidence, but the reliability of the measurements depends mainly on the standardization of procedures. Methodological considerations regarding the establishment of reliability and standardization of the placement of markers are needed in order to offer options for further evaluation reliable for clinical practice. CONCLUSION: Both instruments are reliable and acceptable, but still needed more evidence to support their use of these instruments, because few researchers have used the same study design, and comparison of results between them, are often difficult.en
dc.description.affiliationUniversidade Estadual do Norte Fluminense
dc.description.affiliationUniversidade do Vale do Paraíba
dc.description.affiliationUniversidade Estadual Paulista
dc.description.affiliationUniversidade Federal de Alfenas
dc.description.affiliationNOVAFAPI Faculdade de Ciências Saúde e Tecnologia
dc.description.affiliationUnespUniversidade Estadual Paulista
dc.format.extent389-400
dc.identifierhttp://dx.doi.org/10.1590/S0103-51502011000300003
dc.identifier.citationFisioterapia em Movimento. Pontifícia Universidade Católica do Paraná (PUCPR), v. 24, n. 3, p. 389-400, 2011.
dc.identifier.doi10.1590/S0103-51502011000300003
dc.identifier.fileS0103-51502011000300003.pdf
dc.identifier.issn0103-5150
dc.identifier.scieloS0103-51502011000300003
dc.identifier.urihttp://hdl.handle.net/11449/29137
dc.language.isopor
dc.publisherPontifícia Universidade Católica do Paraná (PUC-PR)
dc.relation.ispartofFisioterapia em Movimento
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectFotogrametriapt
dc.subjectArtrometria articularpt
dc.subjectReprodutibilidade dos testespt
dc.subjectPhotogrammetryen
dc.subjectArthrometry articularen
dc.subjectReproducibility of resultsen
dc.titleConfiabilidade inter e intraexaminadores nas mensurações angulares por fotogrametria digital e goniometriapt
dc.title.alternativeReliability inter and intra-tester in angular measures by photogrammetry versus goniometryen
dc.typeArtigo
dspace.entity.typePublication

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0103-51502011000300003.pdf
Tamanho:
1.53 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções