Logotipo do repositório

Intra-Day and Inter-Day Reliability of Measurements of the electromyographic signal on masseter and temporal muscles in patients with Down syndrome

dc.contributor.authorGiannasi, Lilian Chrystiane [UNESP]
dc.contributor.authorPolitti, Fabiano
dc.contributor.authorDutra, Marignês T. S. [UNESP]
dc.contributor.authorTenguan, Vera L. S. [UNESP]
dc.contributor.authorSilva, Gabriela R. C. [UNESP]
dc.contributor.authorMancilha, Gabriela P. [UNESP]
dc.contributor.authorSilva, Daniel Batista da [UNESP]
dc.contributor.authorOliveira, Luis Vicente Franco
dc.contributor.authorOliveira, Claudia Santos
dc.contributor.authorAmorim, Jose B. O. [UNESP]
dc.contributor.authorSalgado, Miguel Angel Castillo [UNESP]
dc.contributor.authorGomes, Mônica F. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionNove de Julho University
dc.contributor.institutionCentro Universitário de Anápolis - UniEvangélica
dc.date.accessioned2020-12-12T02:40:14Z
dc.date.available2020-12-12T02:40:14Z
dc.date.issued2020-12-01
dc.description.abstractThe aim of the present study was to evaluate intra-day (test) and inter-day (re-test) reliability of surface electromyography (sEMG) signals of the masseter and temporal muscles in patients with Down syndrome (DS). We determined the reliability of sEMG variables in 33 patients with DS. EMG signals were recorded at rest as well as during maximum voluntary clenching and maximum habitual intercuspation (MHI). The signals were analyzed considering the amplitude in the root mean square (RMS), mean frequency (MNF), median frequency (MDF) and approximate entropy (ApEn). The intraclass correlation (ICC2,1) for the three trials recorded during MHI in the two sessions (test and retest) revealed excellent intra-session and inter-session reliability (ICC2,1 = 0.76 to 0.97) for all sEMG variables and muscles. In the rest position, excellent reliability was found for RMS and ApEn (ICC2,1 = 0.75 to 1.00) and good to excellent reliability was found for MDF and MNF (ICC2,1 = 0.64 to 0.93). The intra-session (test) and inter-session (re-test) analyses demonstrated the reliability of nonlinear sEMG variables of the masticatory muscles in adults with Down Syndrome.en
dc.description.affiliationCenter of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE) Institute of Science and Technology São José dos Campos Campus São Paulo State University–UNESP
dc.description.affiliationNove de Julho University
dc.description.affiliationCentro Universitário de Anápolis - UniEvangélica
dc.description.affiliationUnespCenter of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE) Institute of Science and Technology São José dos Campos Campus São Paulo State University–UNESP
dc.identifierhttp://dx.doi.org/10.1038/s41598-020-63963-z
dc.identifier.citationScientific Reports, v. 10, n. 1, 2020.
dc.identifier.dimensionspub.1127346581
dc.identifier.doi10.1038/s41598-020-63963-z
dc.identifier.issn2045-2322
dc.identifier.lattes8235700830441386
dc.identifier.orcid0000-0001-6383-0034
dc.identifier.orcid0000-0001-6609-2794
dc.identifier.orcid0000-0003-3358-5116
dc.identifier.orcid0000-0001-8509-4576
dc.identifier.orcid0000-0002-3852-9415
dc.identifier.orcid0000-0002-8074-6528
dc.identifier.orcid0000-0001-7439-9251
dc.identifier.orcid0000-0001-5793-4013
dc.identifier.pmcidPMC7198527
dc.identifier.pmid32366926
dc.identifier.scopus2-s2.0-85084240607
dc.identifier.urihttp://hdl.handle.net/11449/201728
dc.language.isoeng
dc.publisherSpringer Nature
dc.relation.ispartofScientific Reports
dc.rights.accessRightsAcesso abertopt
dc.rights.sourceRightsoa_all
dc.rights.sourceRightsgold
dc.sourceScopus
dc.sourceDimensions
dc.titleIntra-Day and Inter-Day Reliability of Measurements of the electromyographic signal on masseter and temporal muscles in patients with Down syndromeen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationc73b286a-b5fa-4312-a7ec-62f987e7b514
relation.isOrgUnitOfPublication.latestForDiscoveryc73b286a-b5fa-4312-a7ec-62f987e7b514
unesp.advisor.lattes8235700830441386
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentBiociências e Diagnóstico Bucal - ICTpt

Arquivos