Logotipo do repositório

Harmonizing color measurements in dentistry using translucent tooth-colored materials

dc.contributor.authorTango, Rubens Nisie [UNESP]
dc.contributor.authorMaziero Volpato, Claudia Ângela
dc.contributor.authorSantos, Karina Félix
dc.contributor.authorCesar, Paulo Francisco
dc.contributor.authorParavina, Rade Dušan
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)pt
dc.date.accessioned2026-07-23T11:47:20Z
dc.date.issued2024-02-02
dc.description.abstractBackgroundSince color measurements are relative, the discrepancy among different instruments is alarmingly high. This multicenter study evaluated the effectiveness of instrument calibration and inter-instrument harmonization of different spectrophotometers with the same optical geometry using tooth-colored, translucent dental materials.MethodsThe coordinating center (CC) spectrophotometer was calibrated using the NPL Ceram Series II set. Two sets of 10 specimens, labeled 1 to 10 and I to X (10 mm in diameter and 1 mm thick), were tested at CC and three research sites (RS1, RS2, and RS3) using the same d/8° optical geometry spectrophotometers. Calibration factors were calculated for each material and site to obtain the average calibration factors for sets 1–10, set I-X, and the combination of both. The differences among the non-corrected and corrected reflection values were calculated using CIEDE2000 (DeltaE00) and CIELAB (DeltaEab) color difference formulas and were submitted to ANOVA and Tukey test (α = 0.05).ResultsA significant decrease of color differences between non-corrected as compared to corrected measurements was recorded for all CC-RS and RS-RS comparisons. The reduction of DeltaE00 values between non-corrected and corrected for CC-RS1, CC-RS2, and CC-RS3 were 83.1%, 77.2%, and 73.6%, respectively. The corresponding DeltaE00 values for RS1-RS2, RS1-RS3, and RS2-RS3 comparisons, indirectly compared in the experiment, were 84.2%, 82.8%, and 68.5%, respectively. There was a significant reduction of DeltaE00 and DeltaEab color difference for all combined RS pairs and each of three RS pairs, corrected with one of two specimen sets calibration factors separately.ConclusionsCalibration and harmonization of color measurements in dentistry using tooth-colored, translucent restorative materials significantly decreased measurement discrepancies between the coordinating center and research sites and among pairs of research sites.
dc.description.affiliationSchool of Dentistry, Institute of Science and Technology, Department of Dental Materials and Prosthodontics, Sao Paulo State University, Avenida Eng. Francisco José Longo, 777, 12245320, São José dos Campos, Sao Paulo, Brazil
dc.description.affiliationDepartment of Dentistry, The Federal University of Santa Catarina School of Dentistry, R. Delfino Conti, 1240, 88040-535, Florianópolis - Santa Catarina, Brazil
dc.description.affiliationFaculty of Dentistry, Department Biomaterials and Oral Biology, University of Sao Paulo, Av. Professor Lineu Prestes, 2227, 05508000, Sao Paulo - Sao Paulo, Brazil
dc.description.affiliationDepartment of Restorative Dentistry and Prosthodontics, University of Texas School of Dentistry at Houston, 7500 Cambridge St, 77054, Houston, TX, USA
dc.description.affiliationUnespSchool of Dentistry, Institute of Science and Technology, Department of Dental Materials and Prosthodontics, Sao Paulo State University, Avenida Eng. Francisco José Longo, 777, 12245320, São José dos Campos, Sao Paulo, Brazil
dc.identifierhttps://app.dimensions.ai/details/publication/pub.1168535326
dc.identifier.dimensionspub.1168535326
dc.identifier.doi10.1186/s12903-024-03935-1
dc.identifier.issn1472-6831
dc.identifier.orcid0000-0003-0946-1826
dc.identifier.orcid0000-0003-0918-3678
dc.identifier.orcid0000-0002-7304-4536
dc.identifier.orcid0000-0001-5834-105X
dc.identifier.orcid0000-0002-8459-5528
dc.identifier.pmcidPMC10837962
dc.identifier.pmid38308326
dc.identifier.urihttps://hdl.handle.net/11449/328450
dc.publisherSpringer Nature
dc.relation.ispartofBMC Oral Health; n. 1; v. 24; p. 173
dc.rights.accessRightsAcesso abertopt
dc.rights.sourceRightsoa_all
dc.rights.sourceRightsgold
dc.sourceDimensions
dc.titleHarmonizing color measurements in dentistry using translucent tooth-colored materials
dc.typeArtigopt
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, São José dos Campospt

Arquivos