Logo do repositório
 

Comparison of the accuracy for three dental impression techniques and index: An in vitro study

dc.contributor.authorde Avila, Erica Dorigatti
dc.contributor.authorBarros, Luiz Antônio Borelli [UNESP]
dc.contributor.authorDel'Acqua, Marcelo Antonialli
dc.contributor.authorCastanharo, Sabrina Maria
dc.contributor.authorMollo Jr., Francisco de Assis
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:30:45Z
dc.date.available2014-05-27T11:30:45Z
dc.date.issued2013-09-27
dc.description.abstractObjectives: This in vitro study compared the dimensional accuracy of stone index (I) and three impression techniques: tapered impression copings (T), squared impression copings (S) and modified squared impression copings (MS) for implant-supported prostheses. Methods: A master cast, with four parallel implant abutment analogs and a passive framework, were fabricated. Vinyl polysiloxane impression material was used for all impressions with two metal stock trays (open and closed tray). Four groups (I, T, S and MS) were tested (n = 5). A metallic framework was seated on each of the casts, one abutment screw was tightened, and the gap between the analog of implant and the framework was measured with a stereomicroscope. The groups' measurements (80 gap values) were analyzed using software (LeicaQWin - Leica Imaging Systems Ltd.) that received the images of a video camera coupled to a Leica stereomicroscope at 100× magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, 0.05. Results: The mean values of abutment/framework interface gaps were: Master Cast = 32 μm (SD 2); Group I = 45 μm (SD 3); Group T = 78 μm (SD 25); Group S = 134 μm (SD 30); Group MS = 143 μm (SD 27). No significant difference was detected among Index and Master Cast (P = .05). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast is possible using tapered impression copings techniques and stone index. © 2013 Japan Prosthodontic Society.en
dc.identifierhttp://dx.doi.org/10.1016/j.jpor.2013.07.001
dc.identifier.citationJournal of Prosthodontic Research.
dc.identifier.doi10.1016/j.jpor.2013.07.001
dc.identifier.issn1883-1958
dc.identifier.lattes3085271271577719
dc.identifier.scopus2-s2.0-84884525833
dc.identifier.urihttp://hdl.handle.net/11449/76653
dc.language.isoeng
dc.relation.ispartofJournal of Prosthodontic Research
dc.relation.ispartofjcr3.306
dc.relation.ispartofsjr1,203
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.subjectDental implant
dc.subjectImpression material
dc.subjectImpression technique
dc.subjectTransfer coping
dc.titleComparison of the accuracy for three dental impression techniques and index: An in vitro studyen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication63be3ea1-ddb8-4e20-b4ba-b2c3a2421a32
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes3085271271577719
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt
unesp.departmentOdontologia Social - FOARpt

Arquivos