Logotipo do repositório

Comparison of the accuracy for three dental impression techniques and index: An in vitro study

dc.contributor.authorde Avila, Erica Dorigatti
dc.contributor.authorBarros, Luiz Antônio Borelli [UNESP]
dc.contributor.authorDel'Acqua, Marcelo Antonialli
dc.contributor.authorCastanharo, Sabrina Maria
dc.contributor.authorMollo Jr., Francisco de Assis
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:30:45Z
dc.date.available2014-05-27T11:30:45Z
dc.date.issued2013-09-27
dc.description.abstractObjectives: This in vitro study compared the dimensional accuracy of stone index (I) and three impression techniques: tapered impression copings (T), squared impression copings (S) and modified squared impression copings (MS) for implant-supported prostheses. Methods: A master cast, with four parallel implant abutment analogs and a passive framework, were fabricated. Vinyl polysiloxane impression material was used for all impressions with two metal stock trays (open and closed tray). Four groups (I, T, S and MS) were tested (n = 5). A metallic framework was seated on each of the casts, one abutment screw was tightened, and the gap between the analog of implant and the framework was measured with a stereomicroscope. The groups' measurements (80 gap values) were analyzed using software (LeicaQWin - Leica Imaging Systems Ltd.) that received the images of a video camera coupled to a Leica stereomicroscope at 100× magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, 0.05. Results: The mean values of abutment/framework interface gaps were: Master Cast = 32 μm (SD 2); Group I = 45 μm (SD 3); Group T = 78 μm (SD 25); Group S = 134 μm (SD 30); Group MS = 143 μm (SD 27). No significant difference was detected among Index and Master Cast (P = .05). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast is possible using tapered impression copings techniques and stone index. © 2013 Japan Prosthodontic Society.en
dc.identifierhttp://dx.doi.org/10.1016/j.jpor.2013.07.001
dc.identifier.citationJournal of Prosthodontic Research.
dc.identifier.dimensionspub.1016057362
dc.identifier.doi10.1016/j.jpor.2013.07.001
dc.identifier.issn1883-1958
dc.identifier.issn1883-9207
dc.identifier.issn2212-4632
dc.identifier.lattes3085271271577719
dc.identifier.orcid0000-0001-6681-1269
dc.identifier.orcid0000-0002-4779-1140
dc.identifier.pmid24075828
dc.identifier.scopus2-s2.0-84884525833
dc.identifier.urihttp://hdl.handle.net/11449/76653
dc.language.isoeng
dc.publisherJapan Prosthodontic Society
dc.relation.ispartofJournal of Prosthodontic Research
dc.relation.ispartofjcr3.306
dc.relation.ispartofsjr1,203
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.sourceDimensions
dc.subjectDental implant
dc.subjectImpression material
dc.subjectImpression technique
dc.subjectTransfer coping
dc.titleComparison of the accuracy for three dental impression techniques and index: An in vitro studyen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication63be3ea1-ddb8-4e20-b4ba-b2c3a2421a32
relation.isDepartmentOfPublicationce610400-2137-400b-927a-1106cdca7ed1
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes3085271271577719
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt
unesp.departmentOdontologia Social - FOARpt

Arquivos