Publicação: In vitro microhardness of glass ionomer cements
dc.contributor.author | Silva, R. C. | |
dc.contributor.author | Zuanon, Angela Cristina Cilense [UNESP] | |
dc.contributor.author | Esberard, R. R. | |
dc.contributor.author | Candido, M. S. M. | |
dc.contributor.author | Machado, J. S. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-02-26T17:27:55Z | |
dc.date.accessioned | 2014-05-20T13:44:42Z | |
dc.date.available | 2014-02-26T17:27:55Z | |
dc.date.available | 2014-05-20T13:44:42Z | |
dc.date.issued | 2007-01-01 | |
dc.description.abstract | This study evaluated the surface microhardness of four glass ionomer cements and a composite resin (Fuji IX, Ketac Molar, Vidrion R, Vitromolar and Z 250). Ten specimens of each glass ionomer cement with 8.0 mm diameter and 5.0 mm high dimensions were made and Vicker's microhardness measurements were taken at 1 day and 1 week after initial setting reaction. The results were analyzed using Student's T test and Tukey test (p < 0.05) and demonstrated that the values of microhardness increased after 1 week, with the exception of Fuji IX. Resin composite Z250 presented the greatest values for microhardness. | en |
dc.description.affiliation | Univ São Paulo, Araraquara Dent Sch, Dept Pediat Dent & Orthodont, UNESP, BR-14801903 São Paulo, Brazil | |
dc.description.affiliation | Univ São Paulo, Araraquara Dent Sch, UNESP, Dept Restorat Dent, São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ São Paulo, Araraquara Dent Sch, Dept Pediat Dent & Orthodont, UNESP, BR-14801903 São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ São Paulo, Araraquara Dent Sch, UNESP, Dept Restorat Dent, São Paulo, Brazil | |
dc.format.extent | 139-142 | |
dc.identifier | http://dx.doi.org/10.1007/s10856-006-0672-y | |
dc.identifier.citation | Journal of Materials Science-materials In Medicine. Dordrecht: Springer, v. 18, n. 1, p. 139-142, 2007. | |
dc.identifier.doi | 10.1007/s10856-006-0672-y | |
dc.identifier.issn | 0957-4530 | |
dc.identifier.lattes | 8672541377335694 | |
dc.identifier.uri | http://hdl.handle.net/11449/15675 | |
dc.identifier.wos | WOS:000243257600017 | |
dc.language.iso | eng | |
dc.publisher | Springer | |
dc.relation.ispartof | Journal of Materials Science: Materials in Medicine | |
dc.relation.ispartofjcr | 2.448 | |
dc.relation.ispartofsjr | 0,647 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | In vitro microhardness of glass ionomer cements | en |
dc.type | Artigo | |
dcterms.license | http://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0 | |
dcterms.rightsHolder | Springer | |
dspace.entity.type | Publication | |
unesp.author.lattes | 8672541377335694[2] | |
unesp.author.orcid | 0000-0003-3131-0805[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Clínica Infantil - FOAR | pt |
unesp.department | Odontologia Restauradora - FOAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: