Publicação: Effect of alternative photostimulable phosphor plates erasing times on subjective digital image quality
dc.contributor.author | Melo, D. P. | |
dc.contributor.author | Pontual, A. dos Anjos | |
dc.contributor.author | de Almeida, S. M. | |
dc.contributor.author | Campos, P. S. F. | |
dc.contributor.author | Alves, M. C. | |
dc.contributor.author | Tosoni, Guilherme Monteiro [UNESP] | |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | |
dc.contributor.institution | Universidade Federal de Pernambuco (UFPE) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2013-09-30T18:31:47Z | |
dc.date.accessioned | 2014-05-20T13:45:23Z | |
dc.date.available | 2013-09-30T18:31:47Z | |
dc.date.available | 2014-05-20T13:45:23Z | |
dc.date.issued | 2010-01-01 | |
dc.description.abstract | Objective: To evaluate the influence of alternative erasing times of DenOptix (R) (Dentsply/Gendex, Chicargo, IL) digital plates oil subjective image quality and the probability of double exposure image not Occurring.Methods: Human teeth were X-rayed with phosphor plates using tell different erasing times. Two observers evaluated the images for subjective Image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamal Junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence ora linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring.Results: All 6 parameters or image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image Occurring.Conclusions: The alternative erasing times from 25 s to 130 s showed high quality and no probability of double image Occurrence. Thus, it is possible to reduce the operating time or the DenOptix (R) digital system Without jeopardizing the diagnostic task.Dentomaxillofacial Radiology (2010) 39, 23-27. doi: 10.1259/dmfr/49065239. | en |
dc.description.affiliation | Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Piracicaba, SP, Brazil | |
dc.description.affiliation | Universidade Federal de Pernambuco (UFPE), Pernambuco Dent Sch, Dept Oral Diag, Div Oral Radiol, Camaragibe, PE, Brazil | |
dc.description.affiliation | Univ Estadual Campinas, Piracicaba Dent Sch, Dept Anat, Div Anat, Piracicaba, SP, Brazil | |
dc.description.affiliation | São Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, Div Oral Radiol, Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, Div Oral Radiol, Araraquara, SP, Brazil | |
dc.format.extent | 23-27 | |
dc.identifier | http://dx.doi.org/10.1259/dmfr/49065239 | |
dc.identifier.citation | Dentomaxillofacial Radiology. London: British Inst Radiology, v. 39, n. 1, p. 23-27, 2010. | |
dc.identifier.doi | 10.1259/dmfr/49065239 | |
dc.identifier.issn | 0250-832X | |
dc.identifier.lattes | 0692567697594977 | |
dc.identifier.uri | http://hdl.handle.net/11449/15957 | |
dc.identifier.wos | WOS:000274964100004 | |
dc.language.iso | eng | |
dc.publisher | British Inst Radiology | |
dc.relation.ispartof | Dentomaxillofacial Radiology | |
dc.relation.ispartofjcr | 1.848 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | dental radiography | en |
dc.subject | digital imaging | en |
dc.subject | density | en |
dc.subject | contrast | en |
dc.title | Effect of alternative photostimulable phosphor plates erasing times on subjective digital image quality | en |
dc.type | Artigo | |
dcterms.license | http://www.birjournals.org/site/policy/licence.xhtml | |
dcterms.rightsHolder | British Inst Radiology | |
dspace.entity.type | Publication | |
unesp.author.lattes | 0692567697594977 | |
unesp.author.orcid | 0000-0003-3667-8780[6] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Diagnóstico e Cirurgia - FOAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: