Publicação:
Effect of alternative photostimulable phosphor plates erasing times on subjective digital image quality

dc.contributor.authorMelo, D. P.
dc.contributor.authorPontual, A. dos Anjos
dc.contributor.authorde Almeida, S. M.
dc.contributor.authorCampos, P. S. F.
dc.contributor.authorAlves, M. C.
dc.contributor.authorTosoni, Guilherme Monteiro [UNESP]
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade Federal de Pernambuco (UFPE)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:31:47Z
dc.date.accessioned2014-05-20T13:45:23Z
dc.date.available2013-09-30T18:31:47Z
dc.date.available2014-05-20T13:45:23Z
dc.date.issued2010-01-01
dc.description.abstractObjective: To evaluate the influence of alternative erasing times of DenOptix (R) (Dentsply/Gendex, Chicargo, IL) digital plates oil subjective image quality and the probability of double exposure image not Occurring.Methods: Human teeth were X-rayed with phosphor plates using tell different erasing times. Two observers evaluated the images for subjective Image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamal Junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence ora linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring.Results: All 6 parameters or image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image Occurring.Conclusions: The alternative erasing times from 25 s to 130 s showed high quality and no probability of double image Occurrence. Thus, it is possible to reduce the operating time or the DenOptix (R) digital system Without jeopardizing the diagnostic task.Dentomaxillofacial Radiology (2010) 39, 23-27. doi: 10.1259/dmfr/49065239.en
dc.description.affiliationUniv Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Div Oral Radiol, Piracicaba, SP, Brazil
dc.description.affiliationUniversidade Federal de Pernambuco (UFPE), Pernambuco Dent Sch, Dept Oral Diag, Div Oral Radiol, Camaragibe, PE, Brazil
dc.description.affiliationUniv Estadual Campinas, Piracicaba Dent Sch, Dept Anat, Div Anat, Piracicaba, SP, Brazil
dc.description.affiliationSão Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, Div Oral Radiol, Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, Div Oral Radiol, Araraquara, SP, Brazil
dc.format.extent23-27
dc.identifierhttp://dx.doi.org/10.1259/dmfr/49065239
dc.identifier.citationDentomaxillofacial Radiology. London: British Inst Radiology, v. 39, n. 1, p. 23-27, 2010.
dc.identifier.doi10.1259/dmfr/49065239
dc.identifier.issn0250-832X
dc.identifier.lattes0692567697594977
dc.identifier.urihttp://hdl.handle.net/11449/15957
dc.identifier.wosWOS:000274964100004
dc.language.isoeng
dc.publisherBritish Inst Radiology
dc.relation.ispartofDentomaxillofacial Radiology
dc.relation.ispartofjcr1.848
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectdental radiographyen
dc.subjectdigital imagingen
dc.subjectdensityen
dc.subjectcontrasten
dc.titleEffect of alternative photostimulable phosphor plates erasing times on subjective digital image qualityen
dc.typeArtigo
dcterms.licensehttp://www.birjournals.org/site/policy/licence.xhtml
dcterms.rightsHolderBritish Inst Radiology
dspace.entity.typePublication
unesp.author.lattes0692567697594977
unesp.author.orcid0000-0003-3667-8780[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: