Publicação: Determination of Glycerol in Biodiesel Using a Nickel(II) Oxyhydroxide Chemically Modified Electrode by Cyclic Voltammetry
dc.contributor.author | Pott Marinho Ballottin, Daniela [UNESP] | |
dc.contributor.author | Lataro Paim, Leonardo [UNESP] | |
dc.contributor.author | Ramos Stradiotto, Nelson [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:29:47Z | |
dc.date.available | 2014-05-27T11:29:47Z | |
dc.date.issued | 2013-07-01 | |
dc.description.abstract | A glassy carbon electrode chemically modified with nickel oxyhydroxide from a nickel hexacyanoferrate (NiHCF) film was used to determine glycerol in biodiesel by cyclic voltammetry. The modified electrode exhibited a linear response to glycerol concentration in the range from 0.05 to 0.35mmol L-1, and a detection limit of 0.030mmol L-1. The glycerol concentration found in the biodiesel sample was 0.156mmol L-1. The method developed in this study showed a recovery of (100.3±5.0)%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. | en |
dc.description.affiliation | Analytical Chemistry Department Institute of Chemistry Universidade Estadual Paulista (UNESP), 55 Francisco Degni st, 14800-900, Araraquara, SP | |
dc.description.affiliationUnesp | Analytical Chemistry Department Institute of Chemistry Universidade Estadual Paulista (UNESP), 55 Francisco Degni st, 14800-900, Araraquara, SP | |
dc.format.extent | 1751-1755 | |
dc.identifier | http://dx.doi.org/10.1002/elan.201300090 | |
dc.identifier.citation | Electroanalysis, v. 25, n. 7, p. 1751-1755, 2013. | |
dc.identifier.doi | 10.1002/elan.201300090 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.issn | 1521-4109 | |
dc.identifier.lattes | 0072173018005712 | |
dc.identifier.scopus | 2-s2.0-84880340551 | |
dc.identifier.uri | http://hdl.handle.net/11449/75729 | |
dc.identifier.wos | WOS:000327662000026 | |
dc.language.iso | eng | |
dc.relation.ispartof | Electroanalysis | |
dc.relation.ispartofjcr | 2.851 | |
dc.relation.ispartofsjr | 0,692 | |
dc.relation.ispartofsjr | 0,692 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Scopus | |
dc.subject | Biodiesel | |
dc.subject | Cyclic voltammetry | |
dc.subject | Glycerol | |
dc.subject | Nickel oxy/hydroxide electrode | |
dc.title | Determination of Glycerol in Biodiesel Using a Nickel(II) Oxyhydroxide Chemically Modified Electrode by Cyclic Voltammetry | en |
dc.type | Artigo | |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dspace.entity.type | Publication | |
unesp.author.lattes | 0072173018005712 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |