Logotipo do repositório
 

Publicação:
Determination of Glycerol in Biodiesel Using a Nickel(II) Oxyhydroxide Chemically Modified Electrode by Cyclic Voltammetry

dc.contributor.authorPott Marinho Ballottin, Daniela [UNESP]
dc.contributor.authorLataro Paim, Leonardo [UNESP]
dc.contributor.authorRamos Stradiotto, Nelson [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:29:47Z
dc.date.available2014-05-27T11:29:47Z
dc.date.issued2013-07-01
dc.description.abstractA glassy carbon electrode chemically modified with nickel oxyhydroxide from a nickel hexacyanoferrate (NiHCF) film was used to determine glycerol in biodiesel by cyclic voltammetry. The modified electrode exhibited a linear response to glycerol concentration in the range from 0.05 to 0.35mmol L-1, and a detection limit of 0.030mmol L-1. The glycerol concentration found in the biodiesel sample was 0.156mmol L-1. The method developed in this study showed a recovery of (100.3±5.0)%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.en
dc.description.affiliationAnalytical Chemistry Department Institute of Chemistry Universidade Estadual Paulista (UNESP), 55 Francisco Degni st, 14800-900, Araraquara, SP
dc.description.affiliationUnespAnalytical Chemistry Department Institute of Chemistry Universidade Estadual Paulista (UNESP), 55 Francisco Degni st, 14800-900, Araraquara, SP
dc.format.extent1751-1755
dc.identifierhttp://dx.doi.org/10.1002/elan.201300090
dc.identifier.citationElectroanalysis, v. 25, n. 7, p. 1751-1755, 2013.
dc.identifier.doi10.1002/elan.201300090
dc.identifier.issn1040-0397
dc.identifier.issn1521-4109
dc.identifier.lattes0072173018005712
dc.identifier.scopus2-s2.0-84880340551
dc.identifier.urihttp://hdl.handle.net/11449/75729
dc.identifier.wosWOS:000327662000026
dc.language.isoeng
dc.relation.ispartofElectroanalysis
dc.relation.ispartofjcr2.851
dc.relation.ispartofsjr0,692
dc.relation.ispartofsjr0,692
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectBiodiesel
dc.subjectCyclic voltammetry
dc.subjectGlycerol
dc.subjectNickel oxy/hydroxide electrode
dc.titleDetermination of Glycerol in Biodiesel Using a Nickel(II) Oxyhydroxide Chemically Modified Electrode by Cyclic Voltammetryen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dspace.entity.typePublication
unesp.author.lattes0072173018005712
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt