Logotipo do repositório
 

Publicação:
Maternal and fetal ultrasonography, vulvar temperature and vaginal mucous impedance for the prediction of parturition in Saanen does

dc.contributor.authorDel’Aguila-Silva, Priscila [UNESP]
dc.contributor.authordos Santos, Fabiana Cirino [UNESP]
dc.contributor.authorAires, Luiz Paulo Nogueira [UNESP]
dc.contributor.authorUscategui, Ricardo Andres Ramirez
dc.contributor.authorAmoroso, Lizandra [UNESP]
dc.contributor.authorVicente, Wilter Ricardo Russiano [UNESP]
dc.contributor.authorFeliciano, Marcus Antônio Rossi
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidad CES
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2023-07-29T13:55:44Z
dc.date.available2023-07-29T13:55:44Z
dc.date.issued2023-01-01
dc.description.abstractThe aim of this study was to evaluate and correlate modifications of vaginal mucous impedance, vulvar temperature and ultrasonographic measurements (echobiometric parameters) to parturition in pregnant Saanen does. 30 does were selected for the study and submitted to an estrus synchronization protocol and natural mating. The females were evaluated daily from Day 143 of pregnancy to parturition. For the sonographic evaluations, the following structures were measured: biparietal diameter, thoracic diameter, abdominal diameter, ocular orbit, kidney length, kidney height, cardiac area, placentome length, cervical measurement and fetal heart rate; by means of two different approaches: transrectal and transabdominal, using a 7.5 MHz linear transducer. The vaginal mucous impedance was assessed using an electric estrous detector and vulvar temperature was measured using a non-contact infrared thermometer. Statistical analysis was performed using the R-project software and the significance level was set at 5% for all tests. 25 Saanen does became pregnant, resulting in 80.33% pregnancy rate. Fetal heart rate was negatively correlated to the hours to parturition (p<0,001; r-Pearson= -0,451), as well as vaginal temperature (p= 0,001; r-Pearson= -0,275), while cervical thickness was positively correlated to hours to parturition (p<0,001; r-Pearson= 0,490). The echobiometric parameters (biparietal diameter, thoracic diameter, abdominal diameter, ocular orbit, kidney length and height, cardiac area, placentome length), as well as vaginal mucous impedance did not vary throughout the timepoints of evaluation and did not correlate to the moment of parturition. It was concluded that the parameters of fetal heartbeat, vaginal temperature and cervical effacement in the last week of pregnancy provide valuable information regarding the proximity of parturition.en
dc.description.affiliationDepartamento de Clínica e Cirurgia Veterinária Faculdade de Ciências Agrárias e Veterinárias Universidade Estadual Paulista “Júlio de Mesquita Filho”, SP
dc.description.affiliationDepartamento de Morfologia e Fisiologia Animal Faculdade de Ciências Agrárias e Veterinárias Universidade Estadual Paulista “Júlio de Mesquita Filho”, SP
dc.description.affiliationGrupo de investigación INCA-CES Facultad de Medicina Veterinaria y Zootecnia Universidad CES
dc.description.affiliationDepartamento de Medicina Veterinária Faculdade de Zootecnia e Engenharia de Alimentos Universidade de São Paulo, SP
dc.description.affiliationUnespDepartamento de Clínica e Cirurgia Veterinária Faculdade de Ciências Agrárias e Veterinárias Universidade Estadual Paulista “Júlio de Mesquita Filho”, SP
dc.description.affiliationUnespDepartamento de Morfologia e Fisiologia Animal Faculdade de Ciências Agrárias e Veterinárias Universidade Estadual Paulista “Júlio de Mesquita Filho”, SP
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.identifierhttp://dx.doi.org/10.1590/1984-3143-AR2023-0006
dc.identifier.citationAnimal Reproduction, v. 20, n. 1, 2023.
dc.identifier.doi10.1590/1984-3143-AR2023-0006
dc.identifier.issn1984-3143
dc.identifier.issn1806-9614
dc.identifier.scopus2-s2.0-85159952312
dc.identifier.urihttp://hdl.handle.net/11449/248862
dc.language.isoeng
dc.relation.ispartofAnimal Reproduction
dc.sourceScopus
dc.subjectcaprine
dc.subjectechobiometric
dc.subjectpregnancy
dc.titleMaternal and fetal ultrasonography, vulvar temperature and vaginal mucous impedance for the prediction of parturition in Saanen doesen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.orcid0000-0002-5517-4644[1]
unesp.author.orcid0000-0001-7340-5066[2]
unesp.author.orcid0000-0003-3229-9396[3]
unesp.author.orcid0000-0002-9760-8631[4]
unesp.author.orcid0000-0001-9848-7803[5]
unesp.author.orcid0000-0001-7696-0962[6]
unesp.author.orcid0000-0003-4373-6539[7]
unesp.departmentClínica e Cirurgia Veterinária - FCAVpt
unesp.departmentMorfologia e Fisiologia Animal - FCAVpt

Arquivos