Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2025 a 4 de janeiro de 2026.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

Logo do repositório

Influence of microwave sterilization on the cutting capacity of carbide burs

dc.contributor.authorFais, Laiza Maria Grassi [UNESP]
dc.contributor.authorPinelli, Lígia Antunes Pereira [UNESP]
dc.contributor.authorAdabo, Gelson Luis [UNESP]
dc.contributor.authorda Silva, Regina Helena Barbosa Tavares [UNESP]
dc.contributor.authorMarcelo, Caroline Canhizares [UNESP]
dc.contributor.authorGuaglianoni, Dalton Geraldo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-28T20:59:01Z
dc.date.available2022-04-28T20:59:01Z
dc.date.issued2009-01-01
dc.description.abstractObjective: This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Material and Methods: Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. Results: The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 ± 0.0627 g; G2 = 0.2077 ± 0.0231 g; G3 = 0.1980 ± 0.0326 g; G4 = 0.1203 ± 0.0459 g; G5 = 0.2642 ± 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Conclusion: Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, SP
dc.description.affiliationDepartment of Mathematics and Statistics School of Science and Letters São Paulo State University, Araraquara, SP
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, SP
dc.description.affiliationUnespDepartment of Mathematics and Statistics School of Science and Letters São Paulo State University, Araraquara, SP
dc.format.extent584-589
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572009000600009
dc.identifier.citationJournal of Applied Oral Science, v. 17, n. 6, p. 584-589, 2009.
dc.identifier.doi10.1590/S1678-77572009000600009
dc.identifier.issn1678-7765
dc.identifier.issn1678-7757
dc.identifier.scopus2-s2.0-72549103926
dc.identifier.urihttp://hdl.handle.net/11449/225704
dc.language.isoeng
dc.relation.ispartofJournal of Applied Oral Science
dc.sourceScopus
dc.subjectDental instruments
dc.subjectInfection control
dc.subjectMicrowaves
dc.subjectSterilization
dc.titleInfluence of microwave sterilization on the cutting capacity of carbide bursen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt