Logo do repositório

Three-dimensional finite element analysis of vertical and angular misfit in implant-supported fixed prostheses

dc.contributor.authorAssunção, Wirley Gonçalves [UNESP]
dc.contributor.authorGomes, Érica Alves [UNESP]
dc.contributor.authorRocha, Eduardo Passos [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-29T02:17:16Z
dc.date.available2022-04-29T02:17:16Z
dc.date.issued2011-01-01
dc.description.abstractPurpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 µm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 µm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 µm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. © 2011 by Quintessence Publishing Co Inc.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University (UNESP), São Paulo
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University (UNESP), São Paulo
dc.format.extent788-796
dc.identifier.citationInternational Journal of Oral and Maxillofacial Implants, v. 26, n. 4, p. 788-796, 2011.
dc.identifier.issn0882-2786
dc.identifier.scopus2-s2.0-84555208829
dc.identifier.urihttp://hdl.handle.net/11449/226656
dc.language.isoeng
dc.relation.ispartofInternational Journal of Oral and Maxillofacial Implants
dc.sourceScopus
dc.subjectAbutment stress
dc.subjectBiomechanics
dc.subjectDental implant
dc.subjectDental prosthesis
dc.subjectFinite element analysis
dc.subjectImplant stress
dc.titleThree-dimensional finite element analysis of vertical and angular misfit in implant-supported fixed prosthesesen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos