Publicação:
Comparison between actual and predicted postoperative stair-climbing test, walk test and spirometric values in patients undergoing lung resection

dc.contributor.authorPancieri, Marcos Vinícius Cataneo [UNESP]
dc.contributor.authorCataneo, Daniele Cristina [UNESP]
dc.contributor.authorMontovani, Jair Cortez [UNESP]
dc.contributor.authorCataneo, Antonio José Maria [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:36:48Z
dc.date.available2014-05-20T13:36:48Z
dc.date.issued2010-12-01
dc.description.abstractOBJETIVO: Verificar se os testes: Volume Expiratório Forçado no 1º segundo (VEF1), Teste de Caminhada de 6 minutos (TC6) e Teste de Escada (TE) se alteram proporcionalmente ao pulmão funcionante ressecado. MÉTODOS: Foram incluídos pacientes candidatos a toracotomia para ressecção pulmonar. No pré-operatório (pré) e no mínimo três meses após a cirurgia (pós), realizaram espirometria, TC6 e TE. O TE foi realizado em escada com 12,16m de altura. O tempo para subir todos os degraus o mais rápido possível foi chamado tempo de escada (tTE). Os cálculos dos valores dos testes preditos para o pós-operatório (ppo) foram realizados conforme o número de segmentos funcionantes perdidos. Os valores pré, ppo e pós foram comparados entre si para cada teste. Estatística: foi utilizada a análise de variância para medidas repetidas (ANOVA), com significância de 5%. RESULTADOS: Foram estudados 40 pacientes. A ressecção pulmonar variou desde o ganho de dois segmentos funcionantes até a perda de 9. Os valores pré, ppo e pós foram respectivamente: VEF1 -pré = 2,6±0,8L, ppo = 2,3±0,8L, pós = 2,3±0,8L (VEF1pré > VEF1ppo = VEF1pós), TC6-pré = 604±63m, ppo = 529±103m, pós = 599±74m (TC6pré = TC6pós > TC6ppo), tTE-pré = 32,9±7,6s, ppo = 37,8±12,1s, pós = 33,7±8,5s (tTEpré = tTEpós < tTEppo). CONCLUSÃO: Nas ressecções pulmonares, este grupo de pacientes perdeu função pulmonar medida através da espirometria, mas não perdeu a capacidade de exercício, medida através dos testes de escada e caminhada.pt
dc.description.abstractPURPOSE: To assess whether the tests - Forced Expiratory Volume at one second (FEV1), 6-minute walk test (6MWT) and stair-climbing test (SCT) showed proportional changes after the resection of functioning lung. METHODS: Candidates for pulmonary resection were included. Spirometry, 6MWT and SCT were performed preoperatively (pre) and at least 3 months after surgery (pos). SCT was performed on a staircase with a total ascent height of 12.16m. The time taken to climb the total height the fastest possible was defined as stair-climbing time (SCt). Number of functioning segments lost, was used to calculated predicted postoperative (ppo) tests values. Pre, ppo and pos values for each test were compared. Data were analyzed by repeated-measure ANOVA with significance level set at 5%. RESULTS: A total of 40 patients were enrolled. Pulmonary resection results ranged from gain of 2 functioning segments to loss of 9. Pre, ppo and pos values were the following: preFEV1 = 2.6±0.8L, ppo FEV1 =2.3±0.8L, and pos FEV1=2.3±0.8L, (pre FEV1 > ppo FEV1 = pos FEV1); pre6MWT = 604±63m, ppo6MWT= 529±103m, pos6MWT= 599±74m (pre6MWT = pos6MWT > ppo6MWT); preSCt = 32.9±7.6s, ppoSCt = 37.8±12.1s, posSCt = 33.7±8.5s (preSCt = posSCt < ppoSCt). CONCLUSION: In our group of patients, pulmonary resection led to loss of lung function measured by spirometry, but not to exercise capacity measured by stair-climbing and walk tests.en
dc.description.affiliationUNESP
dc.description.affiliationUNESP Botucatu School of Medicine Department of Surgery
dc.description.affiliationUNESP Botucatu School of Medicine Department of Otorrinolaryngology
dc.description.affiliationUnespUNESP
dc.description.affiliationUnespUNESP Botucatu School of Medicine Department of Surgery
dc.description.affiliationUnespUNESP Botucatu School of Medicine Department of Otorrinolaryngology
dc.format.extent535-540
dc.identifierhttp://dx.doi.org/10.1590/S0102-86502010000600014
dc.identifier.citationActa Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 25, n. 6, p. 535-540, 2010.
dc.identifier.doi10.1590/S0102-86502010000600014
dc.identifier.fileS0102-86502010000600014.pdf
dc.identifier.issn0102-8650
dc.identifier.lattes6121068386940628
dc.identifier.scieloS0102-86502010000600014
dc.identifier.urihttp://hdl.handle.net/11449/12667
dc.identifier.wosWOS:000284779000014
dc.language.isoeng
dc.publisherSociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.relation.ispartofActa Cirúrgica Brasileira
dc.relation.ispartofjcr0.933
dc.relation.ispartofsjr0,395
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectTestes de Função Respiratóriapt
dc.subjectTestes de Função Cardíacapt
dc.subjectEspirometriapt
dc.subjectRespiratory Function Testsen
dc.subjectHeart Function Testsen
dc.subjectSpirometryen
dc.titleComparison between actual and predicted postoperative stair-climbing test, walk test and spirometric values in patients undergoing lung resectionen
dc.title.alternativeComparação dos testes de escada, caminhada e espirometria preditos com os obtidos no pós-operatório de ressecções pulmonarespt
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6121068386940628
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentOftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço - FMBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0102-86502010000600014.pdf
Tamanho:
162.95 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: