Publicação: Photoelastic Stress Analysis of Different Attachment Systems on Implant-Retained and Conventional Palatal Obturator Prostheses
dc.contributor.author | Ribeiro, Paula do Prado [UNESP] | |
dc.contributor.author | Goiato, Marcelo Coelho [UNESP] | |
dc.contributor.author | Pellizzer, Eduardo Piza [UNESP] | |
dc.contributor.author | Pesqueira, Aldieris Alves [UNESP] | |
dc.contributor.author | Haddad, Marcela Filie [UNESP] | |
dc.contributor.author | Rosifini Alves-Rezende, Maria Cristina [UNESP] | |
dc.contributor.author | Santos, Daniela Micheline dos [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2013-09-30T18:29:57Z | |
dc.date.accessioned | 2014-05-20T13:43:38Z | |
dc.date.available | 2013-09-30T18:29:57Z | |
dc.date.available | 2014-05-20T13:43:38Z | |
dc.date.issued | 2011-03-01 | |
dc.description.abstract | Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest. | en |
dc.description.affiliation | UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Aracatuba, SP, Brazil | |
dc.description.affiliationUnesp | UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Aracatuba, SP, Brazil | |
dc.format.extent | 523-526 | |
dc.identifier | http://dx.doi.org/10.1097/SCS.0b013e3182085401 | |
dc.identifier.citation | Journal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 22, n. 2, p. 523-526, 2011. | |
dc.identifier.doi | 10.1097/SCS.0b013e3182085401 | |
dc.identifier.issn | 1049-2275 | |
dc.identifier.lattes | 9719883814872582 | |
dc.identifier.lattes | 5581364193525500 | |
dc.identifier.orcid | 0000-0002-3800-3050 | |
dc.identifier.uri | http://hdl.handle.net/11449/15241 | |
dc.identifier.wos | WOS:000288535800033 | |
dc.language.iso | eng | |
dc.publisher | Lippincott Williams & Wilkins | |
dc.relation.ispartof | Journal of Craniofacial Surgery | |
dc.relation.ispartofjcr | 0.772 | |
dc.relation.ispartofsjr | 0,448 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Photoelastic | en |
dc.subject | implants | en |
dc.subject | obturator prostheses | en |
dc.title | Photoelastic Stress Analysis of Different Attachment Systems on Implant-Retained and Conventional Palatal Obturator Prostheses | en |
dc.type | Artigo | |
dcterms.license | http://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf | |
dcterms.rightsHolder | Lippincott Williams & Wilkins | |
dspace.entity.type | Publication | |
unesp.author.lattes | 9719883814872582 | |
unesp.author.lattes | 5581364193525500 | |
unesp.author.lattes | 2336450644149867[4] | |
unesp.author.orcid | 0000-0002-3800-3050[2] | |
unesp.author.orcid | 0000-0002-1327-9667[6] | |
unesp.author.orcid | 0000-0003-3020-5253[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: