Publicação: Influence of restoration thickness on the stress distribution of ultrathin ceramic onlay rehabilitating canine guidance: A 3D-finite element analysis
dc.contributor.author | Tribst, João P. [UNESP] | |
dc.contributor.author | Kohn, Bianca M. [UNESP] | |
dc.contributor.author | De Oliveira Dal Piva, Amanda M. [UNESP] | |
dc.contributor.author | Spinola, Manuela S. [UNESP] | |
dc.contributor.author | Borges, Alexandre L. [UNESP] | |
dc.contributor.author | Andreatta Filho, Osvaldo D. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2019-10-06T15:42:24Z | |
dc.date.available | 2019-10-06T15:42:24Z | |
dc.date.issued | 2019-06-01 | |
dc.description.abstract | BACKGROUND: The rehabilitation of canine guidance can be performed with adhesive indirect materials, but can the restoration thickness be reduced without mechanical disadvantages? Thus the goal of this study was to analyze the stress of upper canines which received different thicknesses of ceramic fragments for the rehabilitation of the canine guidance using finite element analysis. METHODS: A superior canine was modeled using a computer aided design software. The dental tissues were individually shaped containing enamel, dentin and periodontal ligament. The following three different ceramic fragment thicknesses were then implemented: 0.3, 0.7 and 1.5 mm. Lithium disilicate was chosen as the ceramic material. The solid geometries were exported to the analysis software. The materials were considered isotropic, homogeneous and linear. The set was submitted to efforts in the incisal third in the palatine face to analyze maximal principal stress, mimicking mandibular lateral movement. The applied load was 100N, and the fixation region was on the medullary bone. RESULTS: For restoration, the thinner the ceramic, the higher the stress concentration was; while for the adhesive surface of teeth, the thicker the ceramic, the higher the stress concentration. CONCLUSIONS: The smaller the ceramic thickness was, the lower stress concentration showed at the adhesive interface, while the stress concentration was higher on the restoration intaglio surface. | en |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University Unesp, Avenida Engenheiro Francisco José Longo, 777 | |
dc.description.affiliation | Institute of Science and Technology São Paulo State University Unesp | |
dc.description.affiliation | Department of Restorative Dentistry Institute of Science and Technology São Paulo State University Unesp | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University Unesp, Avenida Engenheiro Francisco José Longo, 777 | |
dc.description.affiliationUnesp | Institute of Science and Technology São Paulo State University Unesp | |
dc.description.affiliationUnesp | Department of Restorative Dentistry Institute of Science and Technology São Paulo State University Unesp | |
dc.format.extent | 126-131 | |
dc.identifier | http://dx.doi.org/10.23736/S0026-4970.19.04183-9 | |
dc.identifier.citation | Minerva Stomatologica, v. 68, n. 3, p. 126-131, 2019. | |
dc.identifier.doi | 10.23736/S0026-4970.19.04183-9 | |
dc.identifier.issn | 1827-174X | |
dc.identifier.issn | 0026-4970 | |
dc.identifier.scopus | 2-s2.0-85065305827 | |
dc.identifier.uri | http://hdl.handle.net/11449/187631 | |
dc.language.iso | eng | |
dc.relation.ispartof | Minerva Stomatologica | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Scopus | |
dc.subject | Ceramics | |
dc.subject | Cuspid | |
dc.subject | Finite element analysis | |
dc.title | Influence of restoration thickness on the stress distribution of ultrathin ceramic onlay rehabilitating canine guidance: A 3D-finite element analysis | en |
dc.type | Artigo | pt |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |