Logo do repositório
 

Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems

dc.contributor.authorFrota, Matheus F. da
dc.contributor.authorEspir, Camila G. [UNESP]
dc.contributor.authorBerbert, Fabio L. C. V. [UNESP]
dc.contributor.authorMarques, Andre A. F.
dc.contributor.authorSponchiado-Junior, Emilio C.
dc.contributor.authorTanomaru-Filho, Mario [UNESP]
dc.contributor.authorGarcia, Lucas F. R. [UNESP]
dc.contributor.authorBonetti-Filho, Idomeo [UNESP]
dc.contributor.institutionUniv Paulista
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionState Univ Amazonas
dc.contributor.institutionUniv Fed Amazonas
dc.date.accessioned2015-03-18T15:56:13Z
dc.date.available2015-03-18T15:56:13Z
dc.date.issued2014-12-01
dc.description.abstractAs compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.en
dc.description.affiliationUniv Paulista, Dept Endodont, Manaus, Amazonas, Brazil
dc.description.affiliationUniv Estadual Paulista, Araraquara Sch Dent, Dept Restorat Dent, Araraquara, SP, Brazil
dc.description.affiliationState Univ Amazonas, Dept Endodont, Manaus, Amazonas, Brazil
dc.description.affiliationUniv Fed Amazonas, Dept Endodont, Manaus, Amazonas, Brazil
dc.description.affiliationUniv Estadual Paulista, Araraquara Sch Dent, Dept Physiol & Pathol, Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Araraquara Sch Dent, Dept Restorat Dent, Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Araraquara Sch Dent, Dept Physiol & Pathol, Araraquara, SP, Brazil
dc.format.extent269-275
dc.identifierhttp://dx.doi.org/10.2334/josnusd.56.269
dc.identifier.citationJournal Of Oral Science. Toyko: Nihon Univ, School Dentistry, v. 56, n. 4, p. 269-275, 2014.
dc.identifier.doi10.2334/josnusd.56.269
dc.identifier.issn1343-4934
dc.identifier.urihttp://hdl.handle.net/11449/117463
dc.identifier.wosWOS:000346628600005
dc.language.isoeng
dc.publisherNihon Univ, School Dentistry
dc.relation.ispartofJournal Of Oral Science
dc.relation.ispartofjcr0.853
dc.relation.ispartofsjr0,397
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectrotary instrumentationen
dc.subjectcyclic fatigueen
dc.subjectreciprocityen
dc.titleComparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systemsen
dc.typeArtigopt
dcterms.rightsHolderNihon Univ, School Dentistry
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublicationb3ba3d9c-022e-4521-8805-0bcceea7372e
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.orcid0000-0002-2574-4706[6]
unesp.author.orcid0000-0001-7677-7682[5]
unesp.author.orcid0000-0001-5230-0492[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentFisiologia e Patologia - FOARpt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos