Logotipo do repositório
 

Publicação:
Decreased fertility in poor responder women is not related to oocyte morphological status

dc.contributor.authorNichi, Marcilio
dc.contributor.authorSavio Figueira, Rita de Cassia
dc.contributor.authorde Almeida Ferreira Braga, Daniela Paes
dc.contributor.authorSetti, Amanda Souza
dc.contributor.authorIaconelli, Assumpto
dc.contributor.authorBorges, Edson [UNESP]
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionFertil Assisted Fertilizat Ctr
dc.contributor.institutionEduc & Res Ctr Assisted Reprod
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:35:28Z
dc.date.available2014-05-20T13:35:28Z
dc.date.issued2011-04-01
dc.description.abstractIntroduction: In women showing impaired fertility, a decreased response to ovarian stimulation is a major problem, limiting the number of oocytes to be used for assisted reproduction techniques (ART). Despite the several definitions of poor response, it is still a matter of debate whether young poor responder patients also show a decrease in oocyte quality. The objective in this study was to investigate whether poor ovarian response to the superstimulation protocol is accompanied by impaired oocyte quality.Material and methods: This study included 313 patients younger than 35 years old, undergoing intracytoplasmic sperm injection. Patients with four or fewer MII oocytes (poor-responder group, PR, n = 57) were age-matched with normoresponder patients (NR, n = 256).Results: A higher rate of oocyte retrieval and a trend towards an increase in MII oocyte rate were observed in the NR group when compared to the PR group (71.6 +/- 1.1% and 74.1 +/- 1.0% vs. 56.3 +/- 2.9% and 66.5 +/- 3.7%; p < 0.0001 and p = 0.056, respectively). A trend toward increased implantation rates was observed in the NR group when compared to the PR group (44 and 24.5 +/- 2.0% vs. 28.8 and 16.4 +/- 3.9%; p = 0.0305 and p = 0.0651, respectively).Conclusions: Low response to ovarian stimulation is apparently not related to impaired oocyte quality. However, embryos produced from poor responder oocytes show impaired capacity to implant and to carry a pregnancy to term.en
dc.description.affiliationUniv São Paulo, Dept Anim Reprod, Fac Vet Med, BR-05508 São Paulo, Brazil
dc.description.affiliationFertil Assisted Fertilizat Ctr, São Paulo, Brazil
dc.description.affiliationEduc & Res Ctr Assisted Reprod, Sapientiae Inst, São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Dept Gynecol & Obstet, Botucatu Med Sch, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Gynecol & Obstet, Botucatu Med Sch, São Paulo, Brazil
dc.format.extent315-320
dc.identifierhttp://dx.doi.org/10.5114/aoms.2011.22084
dc.identifier.citationArchives of Medical Science. Poznan: Termedia Publishing House Ltd, v. 7, n. 2, p. 315-320, 2011.
dc.identifier.doi10.5114/aoms.2011.22084
dc.identifier.issn1734-1922
dc.identifier.urihttp://hdl.handle.net/11449/12209
dc.identifier.wosWOS:000290915100019
dc.language.isoeng
dc.publisherTermedia Publishing House Ltd
dc.relation.ispartofArchives of Medical Science
dc.relation.ispartofjcr2.344
dc.relation.ispartofsjr0,889
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectintracytoplasmic sperm injectionen
dc.subjectovarian stimulationen
dc.subjectoocyte retrievalen
dc.titleDecreased fertility in poor responder women is not related to oocyte morphological statusen
dc.typeArtigo
dcterms.licensehttp://www.termedia.pl/Journal/Archives_of_Medical_Science-19/Dla_autorow
dcterms.rightsHolderTermedia Publishing House Ltd
dspace.entity.typePublication
unesp.author.orcid0000-0003-4262-0825[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentGinecologia e Obstetrícia - FMBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: