Publicação: An impedimetric biosensor to test neat serum for dengue diagnosis
dc.contributor.author | Cecchetto, Juliana [UNESP] | |
dc.contributor.author | Carvalho, Fernanda C. [UNESP] | |
dc.contributor.author | Santos, Adriano [UNESP] | |
dc.contributor.author | Fernandes, Flavio C. B. [UNESP] | |
dc.contributor.author | Bueno, Paulo R. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2015-10-21T20:20:48Z | |
dc.date.available | 2015-10-21T20:20:48Z | |
dc.date.issued | 2015-07-05 | |
dc.description.abstract | NS1, a non-structural dengue protein, has been used as a biomarker for the detection of viremia in dengue diagnosis. In this work, an impedimetric label-free immunosensor based on an anti-NS1 modified gold electrode was developed. To immobilize anti-NS1, a mixed self-assembled monolayer consisting of 11-mercaptoundecanoic acid (for covalent anti-NS1 attachment) and 6-mercaptohexanol (as a spacer) was prepared. The impedance spectra were recorded in the presence of a redox probe ( [Fe(CN)(6)](3-/4-)) to monitor changes in charge-transfer resistance associated with target binding both in PBS and neat serum. A calibration curve was constructed in order to obtain analytical parameters. NS1 was diluted in PBS to final concentrations in the linear range of 0.01-2.00 mu g mL(-1) with a sensitivity of 14.1 percentage decade(-1) (R similar to 0.99) and a limit of detection (LOD) of 3 ng mL(-1). A linear range 0.01-1.00 mu g mL(-1) of NS1 diluted in neat serum was also obtained (R similar to 0.98) with a sensitivity of 10.4 percentage decade(-1) and a LOD of 30 ng mL(-1). The results open new insights into the potential use of this biosensor for point-of-care and bedside applications for dengue diagnosis. | en |
dc.description.affiliation | São Paulo State University (UNESP) - Department of Physical Chemistry, Chemistry Institute, São Paulo, Brazil | |
dc.description.affiliationUnesp | São Paulo State University (UNESP) - Department of Physical Chemistry, Chemistry Institute, São Paulo, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorshipId | FAPESP: 2012-22820-7 | |
dc.format.extent | 150-154 | |
dc.identifier | http://www.sciencedirect.com/science/article/pii/S0925400515002427 | |
dc.identifier.citation | Sensors And Actuators B-chemical. Lausanne: Elsevier Science Sa, v. 213, p. 150-154, 2015. | |
dc.identifier.doi | 10.1016/j.snb.2015.02.068 | |
dc.identifier.issn | 0925-4005 | |
dc.identifier.uri | http://hdl.handle.net/11449/129089 | |
dc.identifier.wos | WOS:000352152500020 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Sensors And Actuators B-chemical | |
dc.relation.ispartofjcr | 5.667 | |
dc.relation.ispartofsjr | 1,406 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Dengue | en |
dc.subject | NS1 protein | en |
dc.subject | Electrochemical impedance spectroscopy (EIS) | en |
dc.subject | Label-free biosensor | en |
dc.subject | Blood serum | en |
dc.title | An impedimetric biosensor to test neat serum for dengue diagnosis | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0003-2827-0208[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Físico-Química - IQAR | pt |