Publicação:
Effects of pigment, disinfection, and accelerated aging on the hardness and deterioration of a facial silicone elastomer

dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorPesqueira, Aldieris Alves [UNESP]
dc.contributor.authorMoreno, Amalia [UNESP]
dc.contributor.authorSantos, Daniela Micheline dos [UNESP]
dc.contributor.authorHaddad, Marcela Filie [UNESP]
dc.contributor.authorBannwart, Lisiane Cristina [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:07Z
dc.date.accessioned2014-05-20T13:43:44Z
dc.date.available2013-09-30T18:30:07Z
dc.date.available2014-05-20T13:43:44Z
dc.date.issued2012-09-01
dc.description.abstractThe failure of facial prostheses is caused by limitations in their flexibility and durability. Therefore, we evaluated the effects of disinfection and aging on Shore A hardness and deterioration of a facial silicone with different pigmentations. Twenty samples with addition of each pigment (ceramic (C), make-up (M)) and without pigment (L) were made. For each pigment type and no pigment, 10 samples were subjected to two types of disinfectant solution (soap (S) and Efferdent (E)), totaling sixty samples. The specimens were disinfected three times per week for 60 days, and subjected to accelerated aging for 1008 h. The hardness of the facial silicone was measured with a durometer, and its deterioration was evaluated by obtaining the weight difference over time. Both the hardness and weight of the samples were measured at baseline, after chemical disinfection, and periodically during accelerated aging (252, 504, and 1008 h). Deterioration was calculated during the periods between baseline and chemical disinfection, and between baseline and each aging period. The results were analyzed using three-way repeated measures ANOVA and the Tukey's HSD Post-hoc test (alpha = 0.05). Specifically, samples containing pigment exhibited significantly higher hardness and deterioration values than those lacking pigment (P < 0.05). In addition, period of time (disinfection and accelerated aging) statistically increased the hardness and deterioration values of the silicone (P < 0.05). It can be concluded that both pigment and time statistically affected the hardness and deterioration of the silicone elastomer. (c) 2012 Elsevier Ltd. All rights reserved.en
dc.description.affiliationUNESP Univ Estadual Paulista, Fac Dent Aracatuba, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Fac Dent Aracatuba, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.format.extent1577-1580
dc.identifierhttp://dx.doi.org/10.1016/j.polymdegradstab.2012.06.033
dc.identifier.citationPolymer Degradation and Stability. Oxford: Elsevier B.V., v. 97, n. 9, p. 1577-1580, 2012.
dc.identifier.doi10.1016/j.polymdegradstab.2012.06.033
dc.identifier.issn0141-3910
dc.identifier.lattes9719883814872582
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.urihttp://hdl.handle.net/11449/15286
dc.identifier.wosWOS:000308051500003
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofPolymer Degradation and Stability
dc.relation.ispartofjcr3.193
dc.relation.ispartofsjr1,041
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectDeteriorationen
dc.subjectPolymeren
dc.subjectDisinfectionen
dc.subjectHardnessen
dc.subjectAccelerated agingen
dc.titleEffects of pigment, disinfection, and accelerated aging on the hardness and deterioration of a facial silicone elastomeren
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.lattes9719883814872582
unesp.author.lattes2336450644149867[2]
unesp.author.orcid0000-0002-3800-3050[1]
unesp.author.orcid0000-0003-3020-5253[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: