dc.description.abstractWe have studied the effects of niobium beam filtration on absorbed doses, on image density and contrast, and on photon spectra with conventional and high-frequency dental x-ray generators. Added niobium reduced entry and superficial absorbed doses in periapical radiography by 9% to 40% with film and digital image receptors, decreased the radiation necessary to produce a given image density on E-speed film and reduced image contrast on D- and E-speed films. As shown by increased half-value layers for aluminum, titanium, and copper and by pulse-height analyses of beam spectra, niobium increased average beam energy by 6% to 19%. Despite the benefits of adding niobium on patient dose reduction and on narrowing the beams' energy spectra, the beam can be overhardened. Adding niobium, therefore, strikes the best balance between radiation dose reduction and beam attenuation, with its risks of increased exposure times, motion blur, and diminished image contrast, when it is used at modest thicknesses (30 μm) and at lower kVp (70) settings. © 1995 Mosby-Year Book, Inc.en
dc.description.affiliationUniversity of Connecticut Health Center School of Dental Medicine Department of Oral Diagnosis, Farmington, Conn
dc.description.affiliationFaculdade de Odontologia de Araraquara-UNESP, Sao Paolo
dc.description.affiliationUnespFaculdade de Odontologia de Araraquara-UNESP, Sao Paolo
dc.format.extent232-241
dc.identifierhttp://dx.doi.org/10.1016/S1079-2104(05)80207-0
dc.identifier.citationOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and, v. 80, n. 2, p. 232-241, 1995.
dc.identifier.doi10.1016/S1079-2104(05)80207-0
dc.identifier.issn1079-2104
dc.identifier.scopus2-s2.0-0029351571
dc.identifier.urihttp://hdl.handle.net/11449/64628
dc.identifier.wosWOS:A1995RN79400019
dc.language.isoeng
dc.relation.ispartofOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.titleNiobium filtration of conventional and high-frequency x-ray generator beams for intraoral radiography. Effects on absorbed doses, image density and contrast, and photon spectraen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos