Publicação:
Effect of phosphate-bonded investments on titanium reaction layer and crown fit

dc.contributor.authorda Rocha, Sicknan Soares
dc.contributor.authorNogueira, Fabiane [UNESP]
dc.contributor.authorPieralini, Anelise Rodolfo Ferreira [UNESP]
dc.contributor.authorRibeiro, Ricardo Faria
dc.contributor.authorAdabo, Gelson Luis [UNESP]
dc.contributor.institutionUniversidade Federal de Goiás (UFG)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-27T11:24:39Z
dc.date.available2014-05-27T11:24:39Z
dc.date.issued2010-04-01
dc.description.abstractThis study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237°C, 75%/287°C, Castorit Super C (CS)-100%/70°C, 75%/141°C and Rematitan Plus (RP)-100%/430°C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (α = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (α = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 μm (204.03 VHN). The group CS 75%/141°C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 μm. The castings made with CS - 100%/70°C presented the lowest levels of marginal misfit, followed by RE -100%/237°C. The conventional investments CS (100%) and RE (100%) showed better marginal fit than RP, but the CS (75%) had higher surface contamination.en
dc.description.affiliationDepartment of Prevention and Oral Rehabilitation Federal University of Goiás, Goiânia, GO
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Faculdade de Odontologia de Araraquara Unesp - Univ Estadual Paulista, Araraquara, SP
dc.description.affiliationDepartment of Dental Materials and Prosthodontics School of Dentistry of Ribeirão Preto University of São Paulo, Ribeirão Preto, SP
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Faculdade de Odontologia de Araraquara Unesp - Univ Estadual Paulista, Araraquara, SP
dc.format.extent147-152
dc.identifierhttp://dx.doi.org/10.1590/S1806-83242010000200004
dc.identifier.citationBrazilian Oral Research, v. 24, n. 2, p. 147-152, 2010.
dc.identifier.doi10.1590/S1806-83242010000200004
dc.identifier.file2-s2.0-77955547448.pdf
dc.identifier.issn1806-8324
dc.identifier.issn1807-3107
dc.identifier.lattes2851339311179809
dc.identifier.scieloS1806-83242010000200004
dc.identifier.scopus2-s2.0-77955547448
dc.identifier.urihttp://hdl.handle.net/11449/71624
dc.language.isoeng
dc.relation.ispartofBrazilian Oral Research
dc.relation.ispartofjcr1.223
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectDental alloys
dc.subjectDental casting investment
dc.subjectDental casting technique
dc.subjectDental prosthesis
dc.subjectTitanium
dc.subjectbiomedical and dental materials
dc.subjectphosphate
dc.subjecttitanium
dc.subjectanalysis of variance
dc.subjectchemistry
dc.subjectdenture
dc.subjectendodontics
dc.subjecthardness
dc.subjectheat
dc.subjectmaterials testing
dc.subjectsurface property
dc.subjecttooth crown
dc.subjectAnalysis of Variance
dc.subjectCrowns
dc.subjectDental Casting Investment
dc.subjectDental Casting Technique
dc.subjectDental Marginal Adaptation
dc.subjectDental Materials
dc.subjectHardness Tests
dc.subjectHot Temperature
dc.subjectMaterials Testing
dc.subjectPhosphates
dc.subjectSurface Properties
dc.titleEffect of phosphate-bonded investments on titanium reaction layer and crown fiten
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/bor/iaboutj.htm
dspace.entity.typePublication
unesp.author.lattes2851339311179809
unesp.author.orcid0000-0002-0734-7926[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-77955547448.pdf
Tamanho:
106.26 KB
Formato:
Adobe Portable Document Format