Logotipo do repositório
 

Publicação:
Radiopacity evaluation of new root canal filling materials by digitalization of images

dc.contributor.authorTanomaru-Filho, Mario
dc.contributor.authorJorge, Erica Gouveia
dc.contributor.authorGuerreiro Tanomaru, Juliane Maria
dc.contributor.authorGonçalves, Marcelo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:46:56Z
dc.date.available2014-05-20T13:46:56Z
dc.date.issued2007-03-01
dc.description.abstractThe aim of this study was to evaluate the radiopacity of five root canal filling materials (AH Plus, Intrafill, Roeko Seal, Epiphany, and EndoRez). Following the International Organization of Standardization 687612001, five circular specimens (10 X 1 mm) were made from each material. After the material set, radiographs were made using occlusal film and a graduated aluminum step-wedge varying in thickness from 2 to 16 mm. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses/second, and distance of 33.5 cm. The radiographs were digitized, and the radiopacity was compared with the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were analyzed using ANOVA and Tukey tests. AH Plus and Epiphany were the most radiopaque materials (9.8 and 8.8 mm Al, respectively), followed by EndoRez (7.2 mm Al). Roeko Seal and Intrafill presented the lowest radiopacity values (5.7 and 6.1 mm Al, respectively). Although the materials evaluated demonstrated different radiopacities, all had values above the minimum recommended by the international Organization of Standardization.en
dc.description.affiliationSão Paulo State Univ, UNESP, Araraquara Dent Sch, Dept Restorat Dent, Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Araraquara Dent Sch, Dept Restorat Dent, Araraquara, SP, Brazil
dc.format.extent249-251
dc.identifierhttp://dx.doi.org/10.1016/j.joen.2006.08.015
dc.identifier.citationJournal of Endodontics. New York: Elsevier B.V., v. 33, n. 3, p. 249-251, 2007.
dc.identifier.doi10.1016/j.joen.2006.08.015
dc.identifier.issn0099-2399
dc.identifier.lattes1067437159861527
dc.identifier.urihttp://hdl.handle.net/11449/16655
dc.identifier.wosWOS:000244586500008
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofJournal of Endodontics
dc.relation.ispartofjcr2.886
dc.relation.ispartofsjr1,585
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectradiologypt
dc.subjectradiopacitypt
dc.subjectroot canal filling materialspt
dc.titleRadiopacity evaluation of new root canal filling materials by digitalization of imagesen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes1067437159861527
unesp.author.orcid0000-0003-0446-2037[3]
unesp.author.orcid0000-0002-2574-4706[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt