Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens
| dc.contributor.author | Queiroz, Marjorie F. N [UNESP] | |
| dc.contributor.author | Ferreira, Felipe Q. T [UNESP] | |
| dc.contributor.author | Shimoda, Gilberto | |
| dc.contributor.author | Padovani, Carlos Roberto [UNESP] | |
| dc.contributor.author | Lottelli, Antonio C [UNESP] | |
| dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
| dc.contributor.institution | Centro de Microcirurgia Ocular Atibaia | |
| dc.date.accessioned | 2022-04-28T16:56:20Z | |
| dc.date.available | 2022-04-28T16:56:20Z | |
| dc.date.issued | 2022-03-21 | |
| dc.description.affiliation | Universidade Estadual Paulista “Júlio de Mesquita Filho, Division of Ophthalmology, Surgical Specialties and Anesthesiology Department | |
| dc.description.affiliation | Centro de Microcirurgia Ocular Atibaia | |
| dc.description.affiliation | Universidade Estadual Paulista “Júlio de Mesquita Filho, Bioscience Institute | |
| dc.description.affiliationUnesp | Universidade Estadual Paulista “Júlio de Mesquita Filho, Division of Ophthalmology, Surgical Specialties and Anesthesiology Department | |
| dc.description.affiliationUnesp | Universidade Estadual Paulista “Júlio de Mesquita Filho, Bioscience Institute | |
| dc.format.extent | - | |
| dc.identifier | http://dx.doi.org/10.5935/0004-2749.20230054 | |
| dc.identifier.citation | Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, p. -, 2022. | |
| dc.identifier.doi | 10.5935/0004-2749.20230054 | |
| dc.identifier.file | S0004-27492022005005220.pdf | |
| dc.identifier.issn | 0004-2749 | |
| dc.identifier.issn | 1678-2925 | |
| dc.identifier.scielo | S0004-27492022005005220 | |
| dc.identifier.uri | http://hdl.handle.net/11449/218215 | |
| dc.language.iso | eng | |
| dc.publisher | Conselho Brasileiro de Oftalmologia | |
| dc.relation.ispartof | Arquivos Brasileiros de Oftalmologia | |
| dc.rights.accessRights | Acesso aberto | pt |
| dc.source | SciELO | |
| dc.subject | Visual acuity | en |
| dc.subject | Quality of life | en |
| dc.subject | Patient satisfaction | en |
| dc.subject | Lens implantation | en |
| dc.subject | intraocular | en |
| dc.subject | Unified Health System | en |
| dc.subject | Acuidade visual | pt |
| dc.subject | Qualidade de vida | pt |
| dc.subject | Satisfação do paciente | pt |
| dc.subject | Implante de lente intraocular | pt |
| dc.subject | Sistema Único de Saúde | pt |
| dc.title | Visual acuity, contrast sensitivity, and quality of life after bilateral implantation of multifocal diffractive intraocular lens | en |
| dc.title.alternative | Acuidade visual, sensibilidade ao contraste e qualidade de vida após implante bilateral de lente intraocular multifocal difrativa | pt |
| dc.type | Artigo | pt |
| dspace.entity.type | Publication | |
| relation.isOrgUnitOfPublication | ab63624f-c491-4ac7-bd2c-767f17ac838d | |
| relation.isOrgUnitOfPublication.latestForDiscovery | ab63624f-c491-4ac7-bd2c-767f17ac838d | |
| unesp.author.orcid | 0000-0002-5306-0176[1] | |
| unesp.author.orcid | 0000-0002-5500-3431[2] | |
| unesp.author.orcid | 0000-0001-5370-4608[5] | |
| unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatu | pt |
| unesp.department | Bioestatística - IBB | pt |
Arquivos
Pacote original
1 - 1 de 1
Carregando...
- Nome:
- S0004-27492022005005220.pdf
- Tamanho:
- 332.16 KB
- Formato:
- Adobe Portable Document Format

