dc.description.abstractThe aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.en
dc.description.affiliationUniv Estadual Paulista, Dept Dent Mat & Prosthodont, UNESP, Aracatuba Sch Dent, São Paulo, Brazil
dc.description.affiliationAraraquara Univ Ctr, Discipline Periodontol, Dent Sch Araraquara, São Paulo, Brazil
dc.description.affiliationAraraquara Univ Ctr, Discipline Integrated Clin, Dent Sch Araraquara, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Dent Mat & Prosthodont, UNESP, Aracatuba Sch Dent, São Paulo, Brazil
dc.format.extent1917-1921
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e3181f4b1a0
dc.identifier.citationJournal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 6, p. 1917-1921, 2010.
dc.identifier.doi10.1097/SCS.0b013e3181f4b1a0
dc.identifier.issn1049-2275
dc.identifier.lattes5581364193525500
dc.identifier.lattes9719883814872582
dc.identifier.lattes3383392287039820
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.urihttp://hdl.handle.net/11449/15329
dc.identifier.wosWOS:000284829800062
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofJournal of Craniofacial Surgery
dc.relation.ispartofjcr0.772
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectProstheses and implantsen
dc.subjecttomographyen
dc.subjectosseointegrationen
dc.titleComputer-Guided Surgery in Implantology: Review of Basic Conceptsen
dc.typeArtigopt
dcterms.licensehttp://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes5581364193525500
unesp.author.lattes9719883814872582
unesp.author.lattes3383392287039820
unesp.author.orcid0000-0002-3800-3050[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: