Publicação: Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration
dc.contributor.author | Nishioka, Renato Sussumu [UNESP] | |
dc.contributor.author | Oliveira de Vasconcellos, Luis Gustavo [UNESP] | |
dc.contributor.author | de Melo Nishioka, Gabriela Nogueira [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T14:05:06Z | |
dc.date.available | 2014-05-20T14:05:06Z | |
dc.date.issued | 2011-04-01 | |
dc.description.abstract | Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse taper were embedded in the center of each polyurethane block in straight placement and offset placement. Four strain gauges (SGs) were bonded on the surface of polyurethane block, which was designated SG1 placed mesially adjacent to implant A, SG2 and SG3 were placed mesially and distally adjacent to the implant B and SG4 was placed distally adjacent to the implant C. The 30 superstructures' occlusal screws were tightened onto the Microunit abutments with a torque of 10 N cm using the manufacturers' manual torque-controlling device.Results: There were statistically significant differences in prosthetic connection (P value = 0.0074 < 0.5). There were no statistically significant differences in placement configuration/alignment (P value = 0.7812 > 0.5).Conclusion: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants. (Implant Dent 2011; 20:e24-e32) | en |
dc.description.affiliation | São Paulo State Univ, UNESP, Dept Dent Mat & Prosthodont, Sch Dent Sao Jose Campos, Sao Jose Dos Campos, Brazil | |
dc.description.affiliation | São Paulo State Univ, UNESP, Sch Dent Araraquara, Araraquara, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Dept Dent Mat & Prosthodont, Sch Dent Sao Jose Campos, Sao Jose Dos Campos, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Sch Dent Araraquara, Araraquara, Brazil | |
dc.format.extent | E24-E32 | |
dc.identifier | http://dx.doi.org/10.1097/ID.0b013e318211fce8 | |
dc.identifier.citation | Implant Dentistry. Philadelphia: Lippincott Williams & Wilkins, v. 20, n. 2, p. E24-E32, 2011. | |
dc.identifier.doi | 10.1097/ID.0b013e318211fce8 | |
dc.identifier.issn | 1056-6163 | |
dc.identifier.lattes | 0056660842284397 | |
dc.identifier.orcid | 0000-0002-1458-601X | |
dc.identifier.uri | http://hdl.handle.net/11449/22831 | |
dc.identifier.wos | WOS:000288942400004 | |
dc.language.iso | eng | |
dc.publisher | Lippincott Williams & Wilkins | |
dc.relation.ispartof | Implant Dentistry | |
dc.relation.ispartofjcr | 1.307 | |
dc.relation.ispartofsjr | 0,712 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | strain development | en |
dc.subject | strain gauge | en |
dc.subject | external hexagon | en |
dc.subject | internal hexagon | en |
dc.subject | Morse taper implant placement | en |
dc.title | Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration | en |
dc.type | Artigo | |
dcterms.license | http://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf | |
dcterms.rightsHolder | Lippincott Williams & Wilkins | |
dspace.entity.type | Publication | |
unesp.author.lattes | 0056660842284397[1] | |
unesp.author.orcid | 0000-0002-1458-601X[1] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: