Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration

dc.contributor.authorNishioka, Renato Sussumu [UNESP]
dc.contributor.authorOliveira de Vasconcellos, Luis Gustavo [UNESP]
dc.contributor.authorde Melo Nishioka, Gabriela Nogueira [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T14:05:06Z
dc.date.available2014-05-20T14:05:06Z
dc.date.issued2011-04-01
dc.description.abstractPurpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse taper were embedded in the center of each polyurethane block in straight placement and offset placement. Four strain gauges (SGs) were bonded on the surface of polyurethane block, which was designated SG1 placed mesially adjacent to implant A, SG2 and SG3 were placed mesially and distally adjacent to the implant B and SG4 was placed distally adjacent to the implant C. The 30 superstructures' occlusal screws were tightened onto the Microunit abutments with a torque of 10 N cm using the manufacturers' manual torque-controlling device.Results: There were statistically significant differences in prosthetic connection (P value = 0.0074 < 0.5). There were no statistically significant differences in placement configuration/alignment (P value = 0.7812 > 0.5).Conclusion: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants. (Implant Dent 2011; 20:e24-e32)en
dc.description.affiliationSão Paulo State Univ, UNESP, Dept Dent Mat & Prosthodont, Sch Dent Sao Jose Campos, Sao Jose Dos Campos, Brazil
dc.description.affiliationSão Paulo State Univ, UNESP, Sch Dent Araraquara, Araraquara, Brazil
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Dept Dent Mat & Prosthodont, Sch Dent Sao Jose Campos, Sao Jose Dos Campos, Brazil
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Sch Dent Araraquara, Araraquara, Brazil
dc.format.extentE24-E32
dc.identifierhttp://dx.doi.org/10.1097/ID.0b013e318211fce8
dc.identifier.citationImplant Dentistry. Philadelphia: Lippincott Williams & Wilkins, v. 20, n. 2, p. E24-E32, 2011.
dc.identifier.doi10.1097/ID.0b013e318211fce8
dc.identifier.issn1056-6163
dc.identifier.lattes0056660842284397
dc.identifier.orcid0000-0002-1458-601X
dc.identifier.urihttp://hdl.handle.net/11449/22831
dc.identifier.wosWOS:000288942400004
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofImplant Dentistry
dc.relation.ispartofjcr1.307
dc.relation.ispartofsjr0,712
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectstrain developmenten
dc.subjectstrain gaugeen
dc.subjectexternal hexagonen
dc.subjectinternal hexagonen
dc.subjectMorse taper implant placementen
dc.titleComparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configurationen
dc.typeArtigo
dcterms.licensehttp://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
unesp.author.lattes0056660842284397[1]
unesp.author.orcid0000-0002-1458-601X[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: