Logo do repositório
 

Influência de diferentes protocolos de fotoativação no grau de conversão e dureza de resinas ortodônticas

dc.contributor.advisorMartins, Lidia Parsekian [UNESP]
dc.contributor.advisorMartins, Renato Parsekian [UNESP]
dc.contributor.authorAmato, Patrícia Alves Ferreira [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:27:54Z
dc.date.available2014-06-11T19:27:54Z
dc.date.issued2012-09-21
dc.description.abstractA presente Dissertação foi composta de dois estudos. O primeiro estudo avaliou in vitro a influência de diferentes tempos de exposição e potências, mantendo-se a mesma energia total, no grau de conversão (GC) e dureza superficial Knoop de três resinas ortodônticas (Transbond XT, Opal Bond MV e Transbond Plus Color Change) fotoativadas por um LED de 3a geração. A análise do GC foi realizada pelo método de Espectroscopia de infravermelho por transformada de Fourier (FT-IR) em nove grupos (n=5) e a dureza superficial Knoop também foi avaliada em nove grupos (n=15), sendo todos os grupos divididos de acordo com as resinas, potências e tempos utilizados. O segundo estudo comparou o GC de duas resinas ortodônticas (Transbond XT e Opal Bond MV) fotoativadas por um LED de 2a geração e um de 3a geração dada uma mesma densidade de energia. A análise do GC foi realizada pelo método de Espectroscopia infravermelho por transformada de Fourier (FT-IR) em quatro grupos (n=5) divididos de acordo com as resinas e gerações de LED utilizados. Os valores obtidos nos dois estudos foram analisados pelo teste ANOVA de dois níveis. No primeiro estudo, as resinas apresentaram iguais graus de conversão quando fotoativadas pelos tempos T1(8,5s) e T2(6s) e menor grau de conversão em T3 (3s). A resina Transbond Plus Color Change apresentou maior grau de conversão, seguido pela Opal Bond MV cujo grau de conversão foi maior que o da Transbond XT. As resinas apresentaram menor dureza quando fotoativadas pelo tempo T1 (8,5s), mas não houve diferença entre os tempos T2 (6s) e T3 (3s). A resina Transbond Plus Color Change apresentou maior dureza superficial do que a Opal Bond MV, sendo ambos os grupos mais duros do que Transbond XT. Foi detectada interação entre as resinas e os tempos utilizados na dureza das resinas. No segundo...pt
dc.description.abstractThe present dissertation consisted of two studies. The first study was aimed at assessing in vitro the influence of different exposure times and potencies, keeping the same total energy, on the degree of conversion and Knoop surface micro-hardness of three orthodontic resins (Transbond XT, Opal Bond MV, and Transbond Plus Colour Change) light-cured with a third-generation LED unit. The second study was aimed at comparing the degree of conversion of two orthodontic resins (Transbond XT and Opal Bond MV) light-cured by using 2nd and 3rd generation LED units operating at the same power density. In the first study, the degree of conversion was assessed by using the Fourier transform infrared spectroscopy (FT-IR) in nine groups (n = 15), whereas the Koop surface micro-hardness was assessed in nine groups, with groups being divided according to the resins, potency and exposure time. In the second study, the degree of conversion was also assessed by using FT-IF in four groups (n = 5) divided according to resins and LEDs used. The values obtained were analysed with two-tailed ANOVA. Resins light-cured at T1 (8.5s) and T2 (6s) showed the same values for degree of conversion, but a lower value at T3 (3s). The Transbond Plus Colour Change resin showed the highest degree of conversion, followed in the order by Opal Bond MV and Transbond XT ones. Resins showed a decreased micro-hardness when light-cured at T1 (8.5s), but no difference was found between T2 (6s) and T3 (3s). The Transbond Plus Colour Change resin showed a greater surface micro-hardness than the Opal Bond MV resin, with both groups being harder than the Transbond XT resin. A relationship between resins and exposure time was found regarding the micro-hardness of these materials. No difference was found between the degrees of conversion of the resins... (Complete abstract click electronic access below)en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent85 f. : il color.
dc.identifier.aleph000720804
dc.identifier.capes33004030010P2
dc.identifier.citationAMATO, Patrícia Alves Ferreira. Influência de diferentes protocolos de fotoativação no grau de conversão e dureza de resinas ortodônticas. 2012. 85 f. Dissertação (mestrado) Universidade Estadual Paulista Julio de Mesquita Filho, Faculdade de Odontologia de Araraquara, 2012.
dc.identifier.fileamato_paf_me_arafo.pdf
dc.identifier.lattes8223795731605246
dc.identifier.urihttp://hdl.handle.net/11449/95762
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.sourceAleph
dc.subjectOrtodontiapt
dc.subjectFourier, Espectroscopia de infravermelho por transformada dept
dc.subjectAdesivospt
dc.subjectOrthodonticspt
dc.titleInfluência de diferentes protocolos de fotoativação no grau de conversão e dureza de resinas ortodônticaspt
dc.typeDissertação de mestradopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes8223795731605246
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.graduateProgramCiências Odontológicas - FOARpt
unesp.knowledgeAreaOrtodontiapt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
amato_paf_me_arafo.pdf
Tamanho:
1.1 MB
Formato:
Adobe Portable Document Format