Shear bond strength fatigue limit of rest seats made with dental restoratives
Carregando...
Data
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Tipo
Artigo
Direito de acesso
Acesso restrito
Resumo
Purpose: This study compared the shear bond strength (SBS) to enamel of rest seats made with a glass-ionomer cement (Fuji IX GP Fast), a resin-modified glass-ionomer cement (Fuji II LC), and a composite resin (Z100 MP) under monotonic and cyclic loading. Materials and Methods: Rest seats were built up onto the lingual surfaces of 80 intact human mandibular incisors. Specimens (n=10) were stored in distilled water at 37°C for 30 days and subjected to shear forces in a universal testing machine (0.5 mm/min) until fracture. The SBS values were calculated (MPa) using the bonding area (9.62 mm2) delimited by adhesive tags. A staircase approach was used to determine the SBS fatigue limit of each material. Specimens were submitted to either 10,000 cycles (5 Hz) or until specimen fracture. A minimum of 15 specimens was tested for each material. Scanning electron microscopy was used to examine the mode of failure. Data were statistically analyzed with one-way ANOVA and Tukey HSD tests (α = 0.05). Results: Z100 MP yielded higher (p < 0.05) SBS (12.25 MPa) than Fuji IX GP Fast (7.21 MPa). No differences were found between Fuji II LC (10.29 MPa) and the other two materials (p > 0.05). Fuji II LC (6.54 MPa) and Z100 MP (6.26 MPa) had a similar SBS limit. Fuji IX GP Fast promoted the lowest (p < 0.05) SBS fatigue limit (2.33 MPa). All samples showed cohesive failure patterns. Conclusion: Fatigue testing can provide a better means of estimating the performance of rest seats made with dental restoratives.
Descrição
Palavras-chave
Composite resins , Dental bonding , Fatigue , Glass-ionomer cements , Shear bond strength , Fuji II LC cement , Fuji IX GP Fast , glass ionomer , resin , silicon dioxide , unclassified drug , Z100 composite resin , zirconium , analysis of variance , comparative study , dental bonding , dental care , denture , enamel , human , incisor , materials testing , shear strength , Analysis of Variance , Composite Resins , Dental Abutments , Dental Bonding , Dental Enamel , Dental Stress Analysis , Denture Retention , Denture, Partial, Removable , Glass Ionomer Cements , Humans , Incisor , Materials Testing , Resins, Synthetic , Shear Strength , Silicon Dioxide , Zirconium
Idioma
Inglês
Citação
Journal of Adhesive Dentistry, v. 9, n. 2, p. 203-208, 2007.





