Publicação: Dosimetry and cost of imaging osseointegrated implants with film-based and computed tomography
dc.contributor.author | Scaf, Gulnara [UNESP] | |
dc.contributor.author | Lurie, Alan G. | |
dc.contributor.author | Mosier, Kristine M. | |
dc.contributor.author | Kantor, Mel L. | |
dc.contributor.author | Ramsby, Gale R. | |
dc.contributor.author | Freedman, Michael L. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | University of Connecticut Health Center (UCHC) | |
dc.contributor.institution | New Jersey Dental School (UMDNJ) | |
dc.date.accessioned | 2014-05-27T11:18:17Z | |
dc.date.available | 2014-05-27T11:18:17Z | |
dc.date.issued | 1997-12-01 | |
dc.description.abstract | Thermoluminescent dosimeters were used to measure radiation doses at craniofacial sites in a tissue-equivalent phantom during film-based multidirectional tomography with the Tomax Ultrascan (Incubation Industries, Ivyland, Pa.) and during computed tomography with the Elscint Excel 2400 (Elscint Corp., Tel Aviv, Israel). Mean absorbed doses for presurgical mandibular and maxillary canine and molar implant assessments were converted to equivalent doses, which were then multipied by published weighting factors and summed to give effective doses. The computed tomgraphy device consistently delivered higher doses than the Tomax Ultrascan to all anatomic locations; the differences were most pronounced when only one or two implant sites were evaluated. The reasons for the dose disparities are considered both anatomically and procedurally. A survey of examination cost revealed film-based multidirectional tomography to be less expensive than computed tomography. | en |
dc.description.affiliation | Oral and Maxillofacial Radiol. Div. Faculdade Odontol. Araraquara-UNESP, Sao Paulo | |
dc.description.affiliation | Div. Oral and Maxillofacial Radiol. Department of Oral Diagnosis Univ. of Connecticut Health Center, Farmington, CT | |
dc.description.affiliation | Div. Oral and Maxillofacial Radiol. UMDNJ-New Jersey Dental School, Newark, NJ | |
dc.description.affiliation | Department of Radiology School of Medicine Univ. of Connecticut Health Center, Farmington, CT | |
dc.description.affiliation | Department of Oral Diagnosis Univ. of Connecticut Health Center School of Dental Medicine, 263 Farmington Avenue, Farmington, CT 06030-1605 | |
dc.description.affiliationUnesp | Oral and Maxillofacial Radiol. Div. Faculdade Odontol. Araraquara-UNESP, Sao Paulo | |
dc.format.extent | 41-48 | |
dc.identifier | http://dx.doi.org/10.1016/S1079-2104(97)90089-5 | |
dc.identifier.citation | Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics, v. 83, n. 1, p. 41-48, 1997. | |
dc.identifier.doi | 10.1016/S1079-2104(97)90089-5 | |
dc.identifier.issn | 1079-2104 | |
dc.identifier.scopus | 2-s2.0-0030637063 | |
dc.identifier.uri | http://hdl.handle.net/11449/65252 | |
dc.identifier.wos | WOS:A1997WD10200013 | |
dc.language.iso | eng | |
dc.relation.ispartof | Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Scopus | |
dc.title | Dosimetry and cost of imaging osseointegrated implants with film-based and computed tomography | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Diagnóstico e Cirurgia - FOAR | pt |