Publicação: BIOMECHANICAL BEHAVIOR OF THE SYSTEM PROSTHESIS/DENTAL IMPLANT: ANALYSIS BY THE PHOTOELASTICITY METHOD
dc.contributor.author | Lopes, Sarah Bessi [UNESP] | |
dc.contributor.author | Correa, Cassia Belloto | |
dc.contributor.author | Araujo, Cleudmar Amaral de | |
dc.contributor.author | Vaz, Luis Geraldo [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2015-03-18T15:56:58Z | |
dc.date.available | 2015-03-18T15:56:58Z | |
dc.date.issued | 2012-01-01 | |
dc.description.abstract | One of the main reasons for the failure in dental implant treatments is the overload, which can cause bone resorption and later, the osseointegration loss in the implant. Therefore, the aim of this study was to analyze the tension generated around dental implants in the rehabilitation of three mandible posterior teeth, varying the connection type, the disposal, and the quantity of implants. The photoelasticity method was used in order to accomplish it. Through photoelasticity, the quantity and localization of the tensions around the implants in the different studied groups were compared (three straight line implants, three offset placement implants, two implants with a mesial cantilever, and two implants with a pontic). The results showed that the tension quantity and disposition around the dental implants of the connection external hexagon and internal hexagon were similar in all groups. In the group where the cantilever was used, an increase of the tension around the implant, adjacent to the cantilever, was observed. From the results it is concluded that the type of connection used in this study did not influence the tension quantity and distribution around the implants; however, the prosthetic configuration with the cantilever use, led to an increase of the tension around the implant, adjacent to the cantilever. | en |
dc.description.affiliation | State Univ Sao Paulo Julio de Mesquita Filho, Dent Sch Araraquara, Dept Dent Mat & Prosthet, Sao Paulo, Brazil | |
dc.description.affiliationUnesp | State Univ Sao Paulo Julio de Mesquita Filho, Dent Sch Araraquara, Dept Dent Mat & Prosthet, Sao Paulo, Brazil | |
dc.format.extent | 2 | |
dc.identifier.citation | Icem15: 15th International Conference On Experimental Mechanics. Porto: Inegi-inst Engenharia Mecanica E Gestao Industrial, 2 p., 2012. | |
dc.identifier.lattes | 8547747556446020 | |
dc.identifier.uri | http://hdl.handle.net/11449/117818 | |
dc.identifier.wos | WOS:000320722900090 | |
dc.language.iso | eng | |
dc.publisher | Inegi-inst Engenharia Mecanica E Gestao Industrial | |
dc.relation.ispartof | Icem15: 15th International Conference On Experimental Mechanics | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | Biomechanics | en |
dc.subject | Dental Implant | en |
dc.subject | Fhotoelasticity Method | en |
dc.title | BIOMECHANICAL BEHAVIOR OF THE SYSTEM PROSTHESIS/DENTAL IMPLANT: ANALYSIS BY THE PHOTOELASTICITY METHOD | en |
dc.type | Trabalho apresentado em evento | |
dcterms.rightsHolder | Inegi-inst Engenharia Mecanica E Gestao Industrial | |
dspace.entity.type | Publication | |
unesp.author.lattes | 8547747556446020 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |