Logotipo do repositório
 

Publicação:
Calibration of frequency domain reflectometry sensors to estimate soil moisture in a Geric Xanthic Ferralsol

dc.contributor.authorAbanto-Rodriguez, Carlos
dc.contributor.authorAraujo, Wellington Farias
dc.contributor.authorChagas, Pollyana Cardoso
dc.contributor.authorChagas, Edvan Alves
dc.contributor.authorMonteiro, Joao Lopes N.
dc.contributor.authorSiqueira, Raphael Da Silva
dc.contributor.authorBarbosa, Samara Martins [UNESP]
dc.contributor.authorMelo, Valdinar Ferreira
dc.contributor.authorMaffei Valero, Miguel A.
dc.contributor.institutionUniv Fed Roraima UFRR
dc.contributor.institutionEmpresa Brasileira de Pesquisa Agropecuária (EMBRAPA)
dc.contributor.institutionInst Fed Roraima IFRR
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2020-12-10T17:31:36Z
dc.date.available2020-12-10T17:31:36Z
dc.date.issued2020-01-01
dc.description.abstractThe use of irrigation is essential to increase crop productivity; however, for efficient water management, it is necessary to more accurately estimate soil moisture. For this reason, the objective in this work was to calibrate FDR model 10HS frequency domain reflectometry sensors (Decagon Devices) for use in a Geric Xanthic Ferralsol type soil. For the calibration, non disturbed soil samples were collected in PVC pipes at two depths (0-20 and 20-40 cm), with four repetitions each and they were placed in trays with distilled water until saturation. Subsequently the sensors were introduced in the sample to obtain the moisture at the saturation point. Then, the samples were placed in an oven at 60 degrees C, until they reached approximately 10 % humidity. The results showed that the gross volumetric moisture data recorded before calibration did not coincide with the 1:1 line, presenting divergent behavior, thus demonstrating the need for calibration. According to the results, it is concluded that the equations generated with the data before the calibration overestimated the volumetric soil moisture, and the equations obtained after the calibration satisfactorily measure the moisture of the Geric Xanthic Ferralsol type soil.en
dc.description.affiliationUniv Fed Roraima UFRR, Programa Posgrad Biodiversidade & Biotecnol Rede, Boa Vista, Parana, Brazil
dc.description.affiliationUniv Fed Roraima UFRR, Boa Vista, Parana, Brazil
dc.description.affiliationEmpresa Brasileira Pesquisa Agr EMBRAPA Roraima, Boa Vista, Parana, Brazil
dc.description.affiliationUniv Fed Roraima UFRR, Programa Posgrad Agron POSAGRO, Boa Vista, Parana, Brazil
dc.description.affiliationInst Fed Roraima IFRR, Boa Vista, Parana, Brazil
dc.description.affiliationUniv Estadual Paulista UNESP, Jaboticabal, Brazil
dc.description.affiliationUnespUniv Estadual Paulista UNESP, Jaboticabal, Brazil
dc.format.extent123-130
dc.identifier.citationBioagro. Barquisimeto-cabudare Lara: Univ Centroccidential Lisandro Alvarado, v. 32, n. 2, p. 123-130, 2020.
dc.identifier.issn1316-3361
dc.identifier.urihttp://hdl.handle.net/11449/195353
dc.identifier.wosWOS:000530873500006
dc.language.isospa
dc.publisherUniv Centroccidential Lisandro Alvarado
dc.relation.ispartofBioagro
dc.sourceWeb of Science
dc.subjectCapacitance
dc.subjectdielectric constant
dc.subjectnon-destructive methods
dc.titleCalibration of frequency domain reflectometry sensors to estimate soil moisture in a Geric Xanthic Ferralsolen
dc.typeArtigopt
dcterms.rightsHolderUniv Centroccidential Lisandro Alvarado
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Agrárias e Veterinárias, Jaboticabalpt

Arquivos