Logotipo do repositório
 

Publicação:
Reliability of Cardiorespiratory Parameters During Cycling Exercise Performed at the Severe Domain in Active Individuals

dc.contributor.authorBarbosa, Luis F. [UNESP]
dc.contributor.authorMontagnana, Lucas [UNESP]
dc.contributor.authorDenadai, Benedito S. [UNESP]
dc.contributor.authorGreco, Camila C. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-12-03T13:11:04Z
dc.date.available2014-12-03T13:11:04Z
dc.date.issued2014-04-01
dc.description.abstractBarbosa, LF, Montagnana, L, Denadai, BS, and Greco, CC. Reliability of cardiorespiratory parameters during cycling exercise performed at the severe domain in active individuals. J Strength Cond Res 28(4): 976-981, 2014-The purpose of this study was to determine the test-retest reliability of cardiorespiratory parameters during cycling exercise performed at severe domain in active individuals. Thirteen active males (24.5 +/- 4.5 years) performed the following tests: (a) an incremental test to determine V ̇o(2)max and the intensity associated with V ̇o(2)max (IV ̇o(2)max); and (b) 4 repetitions of square-wave transitions from rest to a power corresponding to 95%IV ̇o(2)max to determine the parameters of V ̇o(2) kinetics and time to exhaustion (Tlim). Participants performed only 2 transitions on any given day. The interval between the 2 experimental sessions was 48-72 hours. The intraclass correlation coefficient (ICC) and typical error as the coefficient of variation were used to assess reliability. Although the 2 measures of Tlim were moderately related (ICC = 0.78; p < 0.01), Tlim from the second session (545.2 +/- 103.1 seconds) was significantly higher than that of the first (492.5 +/- 100.9 seconds; p = 0.02). Moderate to high reliability (ICC = 0.76-0.93) for the amplitudes of the V ̇o(2) kinetics responses was found. Poor reliability, however, was found for time constants and time delays of the V ̇o(2) kinetics responses. Thus, in nonfamiliarized individuals, Tlim shows a relatively low within-subject coefficient of variation. However, the second score in a series of 2 Tlim tests may be significantly greater than the first. We have also demonstrated that the amplitudes of the V ̇o(2) response have significantly moderate to high reliability. The time-based parameters, however, present an important day-to-day intraindividual variation. Therefore, several transitions are recommended to monitoring changes in an individual over any time frame.en
dc.description.affiliationUNESP, Inst Biosci, Human Performance Lab, Rio Claro, Brazil
dc.description.affiliationUnespUNESP, Inst Biosci, Human Performance Lab, Rio Claro, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipFundação para o Desenvolvimento da UNESP (FUNDUNESP)
dc.format.extent976-981
dc.identifierhttp://dx.doi.org/10.1519/JSC.0b013e3182a1f408
dc.identifier.citationJournal Of Strength And Conditioning Research. Philadelphia: Lippincott Williams & Wilkins, v. 28, n. 4, p. 976-981, 2014.
dc.identifier.doi10.1519/JSC.0b013e3182a1f408
dc.identifier.issn1064-8011
dc.identifier.urihttp://hdl.handle.net/11449/112803
dc.identifier.wosWOS:000333557100015
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofJournal of Strength and Conditioning Research
dc.relation.ispartofjcr2.325
dc.relation.ispartofsjr1,366
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectoxygen uptake kineticsen
dc.subjectslow componenten
dc.subjecttime to exhaustionen
dc.titleReliability of Cardiorespiratory Parameters During Cycling Exercise Performed at the Severe Domain in Active Individualsen
dc.typeArtigo
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
unesp.author.lattes1907479250833033[3]
unesp.author.lattes7416129894680689[4]
unesp.author.orcid0000-0003-0775-1889[3]
unesp.author.orcid0000-0002-7611-9759[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Rio Claropt
unesp.departmentEducação Física - IBpt

Arquivos