Publicação: Reliability of Cardiorespiratory Parameters During Cycling Exercise Performed at the Severe Domain in Active Individuals
dc.contributor.author | Barbosa, Luis F. [UNESP] | |
dc.contributor.author | Montagnana, Lucas [UNESP] | |
dc.contributor.author | Denadai, Benedito S. [UNESP] | |
dc.contributor.author | Greco, Camila C. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-12-03T13:11:04Z | |
dc.date.available | 2014-12-03T13:11:04Z | |
dc.date.issued | 2014-04-01 | |
dc.description.abstract | Barbosa, LF, Montagnana, L, Denadai, BS, and Greco, CC. Reliability of cardiorespiratory parameters during cycling exercise performed at the severe domain in active individuals. J Strength Cond Res 28(4): 976-981, 2014-The purpose of this study was to determine the test-retest reliability of cardiorespiratory parameters during cycling exercise performed at severe domain in active individuals. Thirteen active males (24.5 +/- 4.5 years) performed the following tests: (a) an incremental test to determine V ̇o(2)max and the intensity associated with V ̇o(2)max (IV ̇o(2)max); and (b) 4 repetitions of square-wave transitions from rest to a power corresponding to 95%IV ̇o(2)max to determine the parameters of V ̇o(2) kinetics and time to exhaustion (Tlim). Participants performed only 2 transitions on any given day. The interval between the 2 experimental sessions was 48-72 hours. The intraclass correlation coefficient (ICC) and typical error as the coefficient of variation were used to assess reliability. Although the 2 measures of Tlim were moderately related (ICC = 0.78; p < 0.01), Tlim from the second session (545.2 +/- 103.1 seconds) was significantly higher than that of the first (492.5 +/- 100.9 seconds; p = 0.02). Moderate to high reliability (ICC = 0.76-0.93) for the amplitudes of the V ̇o(2) kinetics responses was found. Poor reliability, however, was found for time constants and time delays of the V ̇o(2) kinetics responses. Thus, in nonfamiliarized individuals, Tlim shows a relatively low within-subject coefficient of variation. However, the second score in a series of 2 Tlim tests may be significantly greater than the first. We have also demonstrated that the amplitudes of the V ̇o(2) response have significantly moderate to high reliability. The time-based parameters, however, present an important day-to-day intraindividual variation. Therefore, several transitions are recommended to monitoring changes in an individual over any time frame. | en |
dc.description.affiliation | UNESP, Inst Biosci, Human Performance Lab, Rio Claro, Brazil | |
dc.description.affiliationUnesp | UNESP, Inst Biosci, Human Performance Lab, Rio Claro, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description.sponsorship | Fundação para o Desenvolvimento da UNESP (FUNDUNESP) | |
dc.format.extent | 976-981 | |
dc.identifier | http://dx.doi.org/10.1519/JSC.0b013e3182a1f408 | |
dc.identifier.citation | Journal Of Strength And Conditioning Research. Philadelphia: Lippincott Williams & Wilkins, v. 28, n. 4, p. 976-981, 2014. | |
dc.identifier.doi | 10.1519/JSC.0b013e3182a1f408 | |
dc.identifier.issn | 1064-8011 | |
dc.identifier.uri | http://hdl.handle.net/11449/112803 | |
dc.identifier.wos | WOS:000333557100015 | |
dc.language.iso | eng | |
dc.publisher | Lippincott Williams & Wilkins | |
dc.relation.ispartof | Journal of Strength and Conditioning Research | |
dc.relation.ispartofjcr | 2.325 | |
dc.relation.ispartofsjr | 1,366 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | oxygen uptake kinetics | en |
dc.subject | slow component | en |
dc.subject | time to exhaustion | en |
dc.title | Reliability of Cardiorespiratory Parameters During Cycling Exercise Performed at the Severe Domain in Active Individuals | en |
dc.type | Artigo | |
dcterms.rightsHolder | Lippincott Williams & Wilkins | |
dspace.entity.type | Publication | |
unesp.author.lattes | 1907479250833033[3] | |
unesp.author.lattes | 7416129894680689[4] | |
unesp.author.orcid | 0000-0003-0775-1889[3] | |
unesp.author.orcid | 0000-0002-7611-9759[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Biociências, Rio Claro | pt |
unesp.department | Educação Física - IB | pt |