Publicação: Cathodic stripping voltammetric detection and determination at a hanging mercury-drop electrode of dye contaminants in purified biomaterials: study of the human serum albumin and reactive dye 120 system
dc.contributor.author | Guaratini, CCI | |
dc.contributor.author | Zanoni, Maria Valnice Boldrin [UNESP] | |
dc.contributor.author | Fogg, A. G. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Loughborough Univ Technol | |
dc.contributor.institution | Univ Luton | |
dc.date.accessioned | 2014-05-20T15:19:57Z | |
dc.date.available | 2014-05-20T15:19:57Z | |
dc.date.issued | 2002-01-01 | |
dc.description.abstract | Procion red HE-3B (RR120) is an example of dye currently used in affinity purification. A method is described for determining trace amounts of RR120 dye contaminant in human serum albumin by cathodic stripping voltammetry. The method is based on a measure of a well-defined peak at -0.58 V, obtained when samples of HSA protein (0.01-2% w/v) containing dye concentrations are submitted to a heating time of 330 min at 80degreesC in NaOH, pH 12.0 and the samples are removed to a solution containing Britton-Robinson buffer, pH 4.0. Using an optimum accumulation potential and tune of 0 V and 240 s, respectively, linear calibration curves were obtained from 1.0 X 10(-9) to 1.0 X 10(-8) mol 1(-1) for RR120 dye. Leakage/hydrolysis of reactive red 120 from an agarose support (e.g. at pH 2 or 12) can also be conveniently determined at very low levels (sub-mug ml(-1)) by means of cathodic stripping voltammetry, which involves adsorptive accumulation of the dye onto the hanging mercury-drop electrode. (C) 2002 Elsevier B.V. B.V. All rights reserved. | en |
dc.description.affiliation | UNESP, Inst Quim, BR-14800900 Araraquara, SP, Brazil | |
dc.description.affiliation | Loughborough Univ Technol, Dept Chem, Loughborough LE11 3TU, Leics, England | |
dc.description.affiliation | Univ Luton, Fac Sci Technol & Design, Sensor & Cryobiol Res Grp, Luton LU1 3JU, Beds, England | |
dc.description.affiliationUnesp | UNESP, Inst Quim, BR-14800900 Araraquara, SP, Brazil | |
dc.format.extent | 65-72 | |
dc.identifier | http://dx.doi.org/10.1016/S0026-265X(01)00141-2 | |
dc.identifier.citation | Microchemical Journal. Amsterdam: Elsevier B.V., v. 71, n. 1, p. 65-72, 2002. | |
dc.identifier.doi | 10.1016/S0026-265X(01)00141-2 | |
dc.identifier.issn | 0026-265X | |
dc.identifier.orcid | 0000-0002-2296-1393 | |
dc.identifier.uri | http://hdl.handle.net/11449/31320 | |
dc.identifier.wos | WOS:000173195500009 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Microchemical Journal | |
dc.relation.ispartofjcr | 2.746 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | dye determination | pt |
dc.subject | human serum albumin | pt |
dc.subject | purified biomaterials | pt |
dc.title | Cathodic stripping voltammetric detection and determination at a hanging mercury-drop electrode of dye contaminants in purified biomaterials: study of the human serum albumin and reactive dye 120 system | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-2296-1393[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: