Logotipo do repositório
 

Publicação:
Cathodic stripping voltammetric detection and determination at a hanging mercury-drop electrode of dye contaminants in purified biomaterials: study of the human serum albumin and reactive dye 120 system

dc.contributor.authorGuaratini, CCI
dc.contributor.authorZanoni, Maria Valnice Boldrin [UNESP]
dc.contributor.authorFogg, A. G.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionLoughborough Univ Technol
dc.contributor.institutionUniv Luton
dc.date.accessioned2014-05-20T15:19:57Z
dc.date.available2014-05-20T15:19:57Z
dc.date.issued2002-01-01
dc.description.abstractProcion red HE-3B (RR120) is an example of dye currently used in affinity purification. A method is described for determining trace amounts of RR120 dye contaminant in human serum albumin by cathodic stripping voltammetry. The method is based on a measure of a well-defined peak at -0.58 V, obtained when samples of HSA protein (0.01-2% w/v) containing dye concentrations are submitted to a heating time of 330 min at 80degreesC in NaOH, pH 12.0 and the samples are removed to a solution containing Britton-Robinson buffer, pH 4.0. Using an optimum accumulation potential and tune of 0 V and 240 s, respectively, linear calibration curves were obtained from 1.0 X 10(-9) to 1.0 X 10(-8) mol 1(-1) for RR120 dye. Leakage/hydrolysis of reactive red 120 from an agarose support (e.g. at pH 2 or 12) can also be conveniently determined at very low levels (sub-mug ml(-1)) by means of cathodic stripping voltammetry, which involves adsorptive accumulation of the dye onto the hanging mercury-drop electrode. (C) 2002 Elsevier B.V. B.V. All rights reserved.en
dc.description.affiliationUNESP, Inst Quim, BR-14800900 Araraquara, SP, Brazil
dc.description.affiliationLoughborough Univ Technol, Dept Chem, Loughborough LE11 3TU, Leics, England
dc.description.affiliationUniv Luton, Fac Sci Technol & Design, Sensor & Cryobiol Res Grp, Luton LU1 3JU, Beds, England
dc.description.affiliationUnespUNESP, Inst Quim, BR-14800900 Araraquara, SP, Brazil
dc.format.extent65-72
dc.identifierhttp://dx.doi.org/10.1016/S0026-265X(01)00141-2
dc.identifier.citationMicrochemical Journal. Amsterdam: Elsevier B.V., v. 71, n. 1, p. 65-72, 2002.
dc.identifier.doi10.1016/S0026-265X(01)00141-2
dc.identifier.issn0026-265X
dc.identifier.orcid0000-0002-2296-1393
dc.identifier.urihttp://hdl.handle.net/11449/31320
dc.identifier.wosWOS:000173195500009
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofMicrochemical Journal
dc.relation.ispartofjcr2.746
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectdye determinationpt
dc.subjecthuman serum albuminpt
dc.subjectpurified biomaterialspt
dc.titleCathodic stripping voltammetric detection and determination at a hanging mercury-drop electrode of dye contaminants in purified biomaterials: study of the human serum albumin and reactive dye 120 systemen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.orcid0000-0002-2296-1393[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: