Logotipo do repositório
 

Publicação:
Extraocular muscle fixation to porous polyethylene orbital implants using 2-octyl-cyanoacrylate

dc.contributor.authorFerraz, Lucieni Cristina Barbarini [UNESP]
dc.contributor.authorSchellini, Silvana A. [UNESP]
dc.contributor.authorWludarski, Sheila L.
dc.contributor.authorPadovani, Carlos R. [UNESP]
dc.contributor.authorSelva, Dinesh
dc.contributor.authorMueller, Sergio [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversity of Adelaide
dc.date.accessioned2022-04-29T08:44:12Z
dc.date.accessioned2014-05-20T13:32:36Z
dc.date.available2022-04-29T08:44:12Z
dc.date.available2014-05-20T13:32:36Z
dc.date.issued2009
dc.description.abstractPurpose. To evaluate the efficacy of bioadhesive in attaching the extraocular muscles to porous polyethylene spheres in rabbit enucleated cavities. Methods. A prospective, experimental study was performed. Eight adult New Zealand white rabbits underwent right enucleation with insertion of an unwrapped 12 mm porous polyethylene sphere. The superior and inferior rectus muscles were attached to the implant with 2-octyl cyanoacrylate placed to the underside of the muscles and application of pressure for 5 seconds. Ninety days after surgery, the orbits were exenterated and four animals underwent histologic evaluation and the other four animals tensile strength testing of the muscle-sphere attachment. Results. There were no exposures or infections of the implants and the muscles remained attached in all cases. Histologic examination showed fibrous tissue reaction at the muscle-sphere attachment with minimal inflammation of the surrounding tissues; a pseudocapsule formation around the spheres and full vascularization of the implant was also observed. There was no evidence of residual glue on histologic examination. Tensile strength testing showed that rupture force was similar between bonded muscle and the porous polyethylene sphere. Conclusions. The 2-octyl-cyanoacrylate did not cause deleterious effects in orbital tissues and provided strong adhesion between muscles and spheres. Bioadhesive may be an option for attaching the extraocular muscles to orbital implants in anophthalmic cavity reconstruction. © Wichtig Editore, 2009.en
dc.description.affiliationOpthalmology Department Faculdade de Medicina de Botucatu da Universidade Estadual Paulista-UNESP, Rubião Junior, s/n, Botucatu-SP 18618-970
dc.description.affiliationPathology Department Consultoria em Patologia, Botucatu, São Paulo
dc.description.affiliationStatistics Department Instituto de Biociências da Universidade Estadual Paulista-UNESP, São Paulo
dc.description.affiliationSouth Australian Institute of Opthalmology Department of Opthalmology and Visual Sciences University of Adelaide, Adelaide, SA
dc.description.affiliationSurgery Department Faculdade de Medicina de Botucatu da Universidade Estadual Paulista-UNESP, São Paulo
dc.description.affiliationUniv Estadual Paulista, Dept Ophthalmol, Fac Med Botucatu, São Paulo, Brazil
dc.description.affiliationConsultoria Patol, Dept Pathol, São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Dept Stat, Inst Biociencias, São Paulo, Brazil
dc.description.affiliationUniv Adelaide, S Australian Inst Ophthalmol, Adelaide, SA 5005, Australia
dc.description.affiliationUniv Adelaide, Dept Ophthalmol & Visual Sci, Adelaide, SA 5005, Australia
dc.description.affiliationUniv Estadual Paulista, Dept Surg, Fac Med Botucatu, São Paulo, Brazil
dc.description.affiliationUnespOpthalmology Department Faculdade de Medicina de Botucatu da Universidade Estadual Paulista-UNESP, Rubião Junior, s/n, Botucatu-SP 18618-970
dc.description.affiliationUnespStatistics Department Instituto de Biociências da Universidade Estadual Paulista-UNESP, São Paulo
dc.description.affiliationUnespSurgery Department Faculdade de Medicina de Botucatu da Universidade Estadual Paulista-UNESP, São Paulo
dc.description.affiliationUnespUniv Estadual Paulista, Dept Ophthalmol, Fac Med Botucatu, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Stat, Inst Biociencias, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Surg, Fac Med Botucatu, São Paulo, Brazil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent527-529
dc.identifierhttp://dx.doi.org/10.1177/112067210901900402
dc.identifierhttp://link.periodicos.capes.gov.br/sfxlcl41?&url_ver=Z39.88-2004&url_ctx_fmt=info:ofi/fmt:kev:mtx:ctx&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Extraocular%20muscle%20fixation%20to%20porous%20polyethylene%20orbital%20implants%20using%202-octyl-cyanoacrylate&rft.aufirst=Lucieni%20Cristina&rft.aulast=Barbarini%20Ferraz&rft.date=2009&rft.epage=529&rft.genre=article&rft.issn=1120-6721&rft.issue=4&rft.jtitle=EUROPEAN%20JOURNAL%20OF%20OPHTHALMOLOGY&rft.pages=527-529&rft.spage=527&rft.stitle=EUR%20J%20OPHTHALMOL&rft.volume=19&rfr_id=info:sid/www.isinet.com:WoK:UA&rft.au=Schellini%2C%20Silvana%20A%2E&rft.au=Wludarski%2C%20Sheila%20L%2E&rft.au=Padovani%2C%20Carlos%20R%2E&rft.au=Selva%2C%20Dinesh
dc.identifier.citationEuropean Journal of Ophthalmology, v. 19, n. 4, p. 527-529, 2009.
dc.identifier.citationEuropean Journal of Ophthalmology. Milan: Wichtig Editore, v. 19, n. 4, p. 527-529, 2009.
dc.identifier.doi10.1177/112067210901900402
dc.identifier.issn1120-6721
dc.identifier.lattes9420249100835492
dc.identifier.scopus2-s2.0-70549089043
dc.identifier.urihttp://hdl.handle.net/11449/243906
dc.identifier.wosWOS:000271844800002
dc.language.isoeng
dc.publisherWichtig Editore
dc.relation.ispartofEuropean Journal of Ophthalmology
dc.relation.ispartofjcr1.897
dc.relation.ispartofsjr0,763
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.sourceWeb of Science
dc.subject2-Octyl cyanoacrylateen
dc.subjectHistologyen
dc.subjectPorous polyethylene sphereen
dc.subjectTensile strength testingen
dc.titleExtraocular muscle fixation to porous polyethylene orbital implants using 2-octyl-cyanoacrylateen
dc.typeArtigo
dcterms.licensehttp://www.vascular-access.info/pub/jva-copyright-transfer-form
dcterms.rightsHolderWichtig Editore
dspace.entity.typePublication
unesp.author.lattes9420249100835492
unesp.author.lattes8727897080522289[4]
unesp.author.orcid0000-0002-7719-9682[4]
unesp.author.orcid0000-0002-6938-1230[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentOftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço - FMBpt
unesp.departmentPatologia - FMBpt

Arquivos