Logotipo do repositório
 

Publicação:
Home dental bleaching monitored with microelectronic sensors to record the wearing times of an acetate tray/bleaching product

dc.contributor.authorPavani, C. C. [UNESP]
dc.contributor.authorSundfeld, D.
dc.contributor.authorSchott, T. C.
dc.contributor.authorBertoz, A. P.M. [UNESP]
dc.contributor.authorBigliazzi, R. [UNESP]
dc.contributor.authorSundfeld, R. H. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionIngá University Center-UNINGA
dc.contributor.institutionEberhard Karls University
dc.date.accessioned2018-12-11T17:21:24Z
dc.date.available2018-12-11T17:21:24Z
dc.date.issued2018-07-01
dc.description.abstractThe present case study quantifies the clinical wearing time of an acetate tray/bleaching product during home dental bleaching. The patient was instructed to use a 10% carbamide peroxide gel for 6-8 hours each day for 20 days. The wearing time of the tray was measured by a microsensor from TheraMon microelectronic system (Sales Agency Gschladt, Hargelsberg, Austria) completely embedded in the tray so that the clinician would be informed as to the precise time the tray was placed in the mouth. Evaluation of the daily printout during dental bleaching demonstrated that the patient did not correctly follow the clinician's instructions as to the wearing time of the tray. Recording the wearing time of dental bleaching agents can be beneficial for both dental professional and patient to obtain a more effective treatment according to the patient's needs and expectations.en
dc.description.affiliationDepartment of Restorative Dentistry Aracatuba Dental School Sao Paulo State University-UNESP
dc.description.affiliationDepartment of Restorative Dentistry and Prosthodontics Ingá University Center-UNINGA
dc.description.affiliationDepartment of Orthodontics and Orofacial Orthopedics Eberhard Karls University
dc.description.affiliationDepartment of Pediatric and Social Dentistry Araçatuba Dental School São Paulo State University-UNESP, 1193 José Bonifácio St
dc.description.affiliationUnespDepartment of Restorative Dentistry Aracatuba Dental School Sao Paulo State University-UNESP
dc.description.affiliationUnespDepartment of Pediatric and Social Dentistry Araçatuba Dental School São Paulo State University-UNESP, 1193 José Bonifácio St
dc.format.extent347-352
dc.identifierhttp://dx.doi.org/10.2341/17-108-S
dc.identifier.citationOperative Dentistry, v. 43, n. 4, p. 347-352, 2018.
dc.identifier.doi10.2341/17-108-S
dc.identifier.issn0361-7734
dc.identifier.scopus2-s2.0-85049587444
dc.identifier.urihttp://hdl.handle.net/11449/176568
dc.language.isoeng
dc.relation.ispartofOperative Dentistry
dc.relation.ispartofsjr1,180
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.titleHome dental bleaching monitored with microelectronic sensors to record the wearing times of an acetate tray/bleaching producten
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes3787326351445431[4]
unesp.author.orcid0000-0002-1746-3138[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentOdontologia Infantil e Social - FOApt
unesp.departmentOdontologia Restauradora - FOApt

Arquivos