dc.date.issued2025-11-18
dc.description.abstractO presente estudo tem como foco a endodontia guiada, uma técnica odontológica inovadora que utiliza do planejamento virtual e impressão 3D para auxiliar no tratamento endodôntico, principalmente em casos complexos de canais calcificados. O objetivo desse trabalho é avaliar dois tipos de guias endodônticos, sendo cinco guias na resina HeyGears e cinco guias na resina Prizma. Foram confeccionados dez corpos de prova, contendo quatro réplicas 3D de dentes unirradiculares em cada um deles, fabricados em poliuretano com propriedades mecânicas e radiográficas semelhantes ao osso maxilar e dentes. Foi realizada tomografia pré-operatória e escaneamento com scanner 3S shape da marca TRIOS ambas as imagens foram integradas no software exocad, em seguida foi realizada a fresagem com um motor de implante da marca Neodent modelo NeoSurgPro (São Paulo, Brasil) com RPM (rotações por minuto) regulado em 900 rotações e torque de 5.0 para garantir um acesso sem resistências ao interior dos condutos. Para o planejamento digital dos corpos de prova foi considerado um acesso de 10 mm (milímetros) para isso foi utilizado um pino de fixação Neodent com 1.3 mm de diâmetro para realização das imagens pós-operatória. Após recebimento das imagens, elas foram reintegradas no software exocad, o pino usado para planejar a posição da fresa permaneceu no mesmo local, enquanto um novo pino foi posicionado ao longo do trajeto que a fresa percorreu na tomografia pós-operatória, possibilitando a comparação das distâncias apical, médio e, cervical entre o planejado e a posição real sobre o conduto fresado. Foi possível concluir que a resina HeyGears apresentou desempenho superior na região apical, com menor desvio em relação ao planejamento digital, quando comparada à resina Prizma, nas regiões médio e cervical, não foram observadas diferenças significativas entre os grupos, sugerindo que ambas as resinas oferecem precisão satisfatória em áreas mais superficiais do conduto radicular.pt
dc.description.abstractThis study focuses on guided endodontics, an innovative dental technique that uses virtual planning and 3D printing to assist in endodontic treatment, particularly in complex cases of calcified canals. The objective of this study was to evaluate two types of endodontic guides, five HeyGears resin guides and five Prizma resin guides. Ten specimens were prepared, each containing four 3D replicas of single-rooted teeth. These were made of polyurethane with mechanical and radiographic properties similar to the jawbone and teeth. Preoperative tomography was performed in the operating room and scanning were performed using a TRIOS 3S shape scanner; both images were integrated into the Exocad software. Followed by milling with a Neodent implant motor NeoSurgPro model (São Paulo, Brazil) with a 900 rpm (revolutions per minute) and a torque of 5.0 to ensure resistance-free access to the inside of the canals. For digital planning of the specimens, a 10 mm (millimeter) access was considered, and a 1.3 mm diameter Neodent fixation pin was used to obtain postoperative images. After receiving the images, they were reintegrated into the software. The pin used to plan the reamer position remained in the same location, while a new pin was positioned along the path the bur traveled in the postoperative CT scan, allowing comparison of the apical and cervical distances between the planned and the actual position on the milled canal. It was possible to conclude that HeyGears resin showed superior performance in the apical region, with less deviation from digital planning, when compared to Prizma resin. In the middle and cervical regions, no significant differences were observed between the groups, suggesting that both resins offer satisfactory precision in more superficial areas of the root canal.en
dc.description.sponsorshipIdnão recebi financiamento
dc.identifier.capes33004030170P0
dc.identifier.citationSILVA, L. A. P. Análise de resinas na confecção de guias cirúrgicos endodônticos. 2026. 48 p. Dissertação (Mestrado em Engenharia de Biomateriais e Bioprocesso) - Faculdade de Ciências Farmacêuticas, Universidade Estadual Paulista (UNESP), Araraquara, 2025.
dc.identifier.lattes6780393877192680
dc.identifier.orcid0009-0008-9609-3518
dc.identifier.urihttps://hdl.handle.net/11449/319369
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso restritopt
dc.subjectendodontia guiadapt
dc.subjectfresagempt
dc.subjectresina 3Dpt
dc.subjectendodontiapt
dc.subjectimpressão tridimensionalpt
dc.subjectgomas e resinas sintéticaspt
dc.titleAnálise de resinas na confecção de guias cirúrgicos endodônticospt
dc.title.alternativeAnalysis of resins in the manufacture of endodontic surgical guidesen
dc.typeDissertação de mestradopt
dspace.entity.typePublication
relation.isGradProgramOfPublicationf8bd4449-4356-434b-8476-120f2d21a1bb
relation.isGradProgramOfPublication.latestForDiscoveryf8bd4449-4356-434b-8476-120f2d21a1bb
relation.isOrgUnitOfPublication95697b0b-8977-4af6-88d5-c29c80b5ee92
relation.isOrgUnitOfPublication.latestForDiscovery95697b0b-8977-4af6-88d5-c29c80b5ee92
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Farmacêuticas, Araraquarapt
unesp.embargo12 meses após a data da defesapt
unesp.examinationboard.typeBanca públicapt
unesp.graduateProgramEngenharia de Biomateriais e Bioprocessos - FCFpt
unesp.knowledgeAreaBiomateriaispt
unesp.researchAreaEndodontiapt

Arquivos

Pacote original

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
silva_lap_me_arafcf_int.pdf
Tamanho:
1.79 MB
Formato:
Adobe Portable Document Format
Carregando...
Imagem de Miniatura
Nome:
silva_lap_me_arafcf_par.pdf
Tamanho:
1.9 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
2.14 KB
Formato:
Item-specific license agreed upon to submission
Descrição: