Publicação: Influence of length and diameter of implants associated with distal extension removable partial dentures
dc.contributor.author | Verri, Fellippo Ramos [UNESP] | |
dc.contributor.author | Pellizzer, Eduardo Piza [UNESP] | |
dc.contributor.author | Rocha, Eduardo Passos [UNESP] | |
dc.contributor.author | Pereira, João Antônio [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:22:35Z | |
dc.date.available | 2014-05-27T11:22:35Z | |
dc.date.issued | 2007-09-17 | |
dc.description.abstract | PURPOSE | en |
dc.description.affiliation | Dentistry Faculty of Araçatuba UNESP, Araçatuba, São Paulo | |
dc.description.affiliation | Dental Materials and Prosthesis Department Dentistry Faculty of Araçatuba-UNESP, Araçatuba, São Paulo | |
dc.description.affiliation | Mechanical Engineering Department Ilha Solteira Engineering Faculty-UNESP, Ilha Solteira, São Paulo | |
dc.description.affiliation | , Vila Mendonca 16.015-050, Araçatuba, São Paulo | |
dc.description.affiliationUnesp | Dentistry Faculty of Araçatuba UNESP, Araçatuba, São Paulo | |
dc.description.affiliationUnesp | Dental Materials and Prosthesis Department Dentistry Faculty of Araçatuba-UNESP, Araçatuba, São Paulo | |
dc.description.affiliationUnesp | Mechanical Engineering Department Ilha Solteira Engineering Faculty-UNESP, Ilha Solteira, São Paulo | |
dc.format.extent | 270-280 | |
dc.identifier | http://dx.doi.org/10.1097/ID.0b013e31805007aa | |
dc.identifier.citation | Implant Dentistry, v. 16, n. 3, p. 270-280, 2007. | |
dc.identifier.doi | 10.1097/ID.0b013e31805007aa | |
dc.identifier.issn | 1056-6163 | |
dc.identifier.lattes | 5581364193525500 | |
dc.identifier.lattes | 3383392287039820 | |
dc.identifier.scopus | 2-s2.0-34548552947 | |
dc.identifier.uri | http://hdl.handle.net/11449/69886 | |
dc.language.iso | eng | |
dc.relation.ispartof | Implant Dentistry | |
dc.relation.ispartofjcr | 1.307 | |
dc.relation.ispartofsjr | 0,712 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Scopus | |
dc.subject | Biomechanics | |
dc.subject | Dental implant | |
dc.subject | Finite element analysis | |
dc.subject | Removable partial denture | |
dc.subject | computer aided design | |
dc.subject | dental care | |
dc.subject | denture | |
dc.subject | finite element analysis | |
dc.subject | mandible | |
dc.subject | methodology | |
dc.subject | tooth implantation | |
dc.subject | tooth prosthesis | |
dc.subject | Computer-Aided Design | |
dc.subject | Dental Implants | |
dc.subject | Dental Models | |
dc.subject | Dental Prosthesis, Implant-Supported | |
dc.subject | Denture, Partial, Removable | |
dc.subject | Finite Element Analysis | |
dc.subject | Mandible | |
dc.title | Influence of length and diameter of implants associated with distal extension removable partial dentures | en |
dc.type | Artigo | pt |
dcterms.license | http://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf | |
dspace.entity.type | Publication | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 0224087261544502 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteira | pt |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Engenharia Mecânica - FEIS | pt |