Logotipo do repositório
 

Publicação:
Effect of Combined Digital Imaging Parameters on Endodontic File Measurements

dc.contributor.authorde Oliveira, Matheus Lima
dc.contributor.authorde Souza Pinto, Geraldo Camilo [UNESP]
dc.contributor.authorBovi Ambrosano, Glaucia Maria
dc.contributor.authorTosoni, Guilherme Monteiro [UNESP]
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:31:59Z
dc.date.accessioned2014-05-20T13:45:29Z
dc.date.available2013-09-30T18:31:59Z
dc.date.available2014-05-20T13:45:29Z
dc.date.issued2012-10-01
dc.description.abstractIntroduction: This study assessed the effect of the combination of a dedicated endodontic filter, spatial resolution, and contrast resolution on the determination of endodontic file lengths. Methods: Forty extracted single-rooted teeth were x-rayed with K-files (ISO size 10 and 15) in the root canals. Images were acquired using the Vista Scan system (Durr Dental, Beitigheim-Bissingen, Germany) under different combining parameters of spatial resolution (10 and 25 line pairs per millimeter [lp/mm]) and contrast resolution (8- and 16-bit depths). Subsequently, a dedicated endodontic filter was applied on the 16-bit images, creating 2 additional parameters. Six observers measured the length of the endodontic files in the root canals using the software that accompanies the system. The mean values of the actual file lengths and the measurements of the radiographic images were submitted to 1-way analysis of variance and the Tukey test at a level of significance of 5%. The intraobserver reproducibility was assessed by the intraclass correlation coefficient. Results: All combined image parameters showed excellent intraobserver agreement with intraclass correlation coefficient means higher than 0.98. The imaging parameter of 25 lp/mm and 16 bit associated with the use of the endodontic filter did not differ significantly from the actual file lengths when both file sizes were analyzed together or separately (P > .05). When the size 15 file was evaluated separately, only 8-bit images differed significantly from the actual file lengths (P <= .05). Conclusions: The combination of an endodontic filter with high spatial resolution and high contrast resolution is recommended for the determination of file lengths when using storage phosphor plates. (J Endod 2012;38:1404-1407)en
dc.description.affiliationUniv Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, São Paulo, Brazil
dc.description.affiliationUniv Estadual Campinas, Piracicaba Dent Sch, Dept Social Dent, São Paulo, Brazil
dc.description.affiliationSão Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Araraquara Dent Sch, Dept Oral Diag & Surg, São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 08/01715-5
dc.format.extent1404-1407
dc.identifierhttp://dx.doi.org/10.1016/j.joen.2012.06.006
dc.identifier.citationJournal of Endodontics. New York: Elsevier B.V., v. 38, n. 10, p. 1404-1407, 2012.
dc.identifier.doi10.1016/j.joen.2012.06.006
dc.identifier.issn0099-2399
dc.identifier.lattes0692567697594977
dc.identifier.urihttp://hdl.handle.net/11449/16008
dc.identifier.wosWOS:000309377000022
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofJournal of Endodontics
dc.relation.ispartofjcr2.886
dc.relation.ispartofsjr1,585
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectDigital dental radiographyen
dc.subjectendodonticsen
dc.subjectodontometryen
dc.subjectsoftwareen
dc.titleEffect of Combined Digital Imaging Parameters on Endodontic File Measurementsen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes0692567697594977
unesp.author.orcid0000-0002-8054-8759[1]
unesp.author.orcid0000-0003-3667-8780[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: